53
Enforcer V10 Programming Guide
APPENDIX E. FAULT FINDING
If a device on the Enforcer is not installed correctly or has lost its communication with the panel, “DEVICE FAIL” will
be shown on the keypad as shown:
Control Panel = Main panel fault (e.g. battery)
485 Fail Kpd = Keypad
485 Fail Trd
= Tag Reader / Door Station / TMZ
485 Fail Zem = Zone Expander Module (ZEM)
485 Fail Opm = Output Module
For the keypad and tag readers, the top line will show the set point name, for the ZEMs and output modules a
‘Location’ description (if inputted) will be shown on the top line of the display instead of the address number.
(Address number will be displayed in 2 digits, e.g.: 00,01,02 etc).
Wireless Fault Displays
FAULT
DESCRIPTION
SOLUTION
Wireless mismatch
There is an input learnt without having a
type assigned to it
Assign an input type in ‘Change Inputs’.
User name
Wireless Low Bat
Low battery on radio keyfob for the user
with the name shown on the top line.
Replace the battery on the mentioned
keyfob.
Input name
Wireless Low Bat
Low battery on radio input, entered
name of input shown on top line.
Replace the battery on the mentioned
input device.
Siren n
Wireless Low Bat
Low battery on radio bell number ‘n’
Replace the battery on the mentioned
radio bell.
Input name
Wireless Supervision fault
Radio input whose name is shown on
the top line hasn’t ‘checked in’
Walk test the detector, perform a
diagnostic – signal strength test and try
replacing the battery.
Siren n
Wireless Supervision fault
Radio bell number ‘n’ hasn’t ‘checked in’
Test the siren, perform a diagnostic –
signal strength test and try replacing the
battery.
Input name
Tamper Alarm
Tamper fault on radio input whose
name is shown on the top line
Check the tamper switch on mentioned
radio input; check that the case is closed
properly.
Siren n
Tamper Alarm
Tamper fault on radio bell number ‘n’
Check the tamper switch on the
mentioned radio bell.
Location
Wireless Jam WZm
Jamming fault on the wireless ZEM
whose location is shown on the top line
Check no radio interference is in close
proximity to the radio devices/panel.
“Input name” or
“Siren n”
Wirless Poll Fail
No ‘polls’ are received for 20 minutes
before the set operation
Test the signal strength / battery on the
device shown.