20
Enforcer V10 Programming Guide
Entry Control or Access Control
1.
Press
or
to scroll to ‘ASSIGN KEYPADS/READERS’. Press
.
2.
Press
[
or
]
to select the address. Press
.
3.
‘Type’ will be displayed. Press
to select the reader. Press
.
4.
‘Reader is’ will be displayed. Press
2
for ‘Access Control’ or press 4 for ‘Entry
Control’ Press
.
5.
‘Set Point Sets’ will be displayed. Select the area(s). Press
. Set Point Unsets’
will be displayed. Select the area(s). Press
. ‘Set Point In’ will be displayed.
Select the area(s). Press
.
6.
‘Lock Open Time’ will be displayed. Enter the Lock Open Time in seconds and
press
. (Max 255 seconds).
7.
‘Door Open Time’ will be displayed. Enter the Door Open Time in seconds and
press
. (Max 255 seconds).
8.
‘Access Control Description’ will be displayed. Press
.
9.
‘Enter Name’ will be displayed. Enter the name of the keypad and press
.
10. ‘Enter Location’ will be displayed. Enter the location of the keypad and press
.
11. Press
[
or
]
to select another device address to program (0-3) or press
the
key to return to the Engineer menu.
Wireless Arming Station Options
Tag Read Enable
Enables the proximity tag reader on the wireless arming station.
Auto Wakeup
Forces the keypad to automatically wake up when an entry time is initiated.
Supervision
When switched to ‘Yes’ the control panel will supervise the signal of the wireless arming station.
Back Light
Toggles the LCD backlight on or off.
Entry/Exit Sound
When enabled, the arming station will mimic the entry/exit tones of the panel.
Set Point Sets
Enter the areas that the arming station is permitted to set.
Set Points Unsets
Enter the areas that the arming station is permitted to unset.