Enforcer V10 Programming Guide
FAULT
DESCRIPTION
SOLUTION
Bat Test Fail XXX
Battery Load Test has failed
Only displays if option selected.
Battery uncharged or capacity below
specification may need replacing. Same
method as showing the device as
battery fault.
Bat Critical XXX
Battery being powered down
Protects battery from deep discharge
damage during extended mains failure.
Same method as showing the device as
battery fault.
Note: System is now powered down
Mains Fail xxx
Mains supply failed
System detects mains frequency out
of specification, as well as voltage.
Same method as showing the device
as battery fault. Note: 'AC FAIL' timer
operative
Low Volts xxx
Power supply volts low
Battery volts below normal ‘battery fault’
level during mains failure. Same method
as showing the device as battery fault
Detection Faults
FAULT
DESCRIPTION
SOLUTION
Case Tamper XXX
Case tamper switch open
Secure switch closed. Same method of
showing the device as battery fault.
Communication Faults
FAULT
DESCRIPTION
SOLUTION
Control Panel Modem
Fault
End Station unable to communicate
with Digi Modem
If modem not present, ensure that
“Disable Digi” option is set to ‘YES’ and
“DOWNLOAD MODE” is set to ‘NONE’
or ‘RS232’. If present, but not detected,
check the modem is inserted correctly.
Control Panel ARC Call
Fail
Call to ARC from Digi Modem Digi
Modem has failed. Note: This is a
communication problem, which is rarely
caused by an equipment fault.
Check ALL call details are programmed
correctly. Ensure signalling format is
correctly set for ARC receiver. Ensure
that calls to the ARC or SMS bureaux
numbers are allowed on the PSTN line,
eg 0800, 0845 etc.
Control Panel Line Fault
100
PSTN Line Fault signalled by Digi
Modem.
Only operative if "DOWNLOAD BY
MODEM" selected OR "DISABLE DIGI/
SMS" is set to 'NO'.
Note: ‘Line Fault’ timer operative.