25
Enforcer V10 Programming Guide
Simple Set
If ‘YES’, the Enforcer allows a user to set the system ‘quickly’ by pressing
and then the Area (A, B, C or D).
Please note: This must not be enabled when BS8243 option 6.4.5 is in use.
Intelligent Set
The system has the facility to automatically initiate a different set mode or area when you activate an input in a
certain area (rather than having to choose a different Set mode via the keypad). This is known as “Intelligent Setting”.
Please note that when Intelligent Setting has been enabled, the exit tone will commence at ‘intelligent’ volume.
When intelligent set is enabled, then level set B will start to set (if the user code is enabled in level set B). Then if a
Final Exit input is activated, which is programmed in level set A during the exit time, then the panel will automatically
‘quick set’ in level set A.
Please note: Intelligent Set only works when the panel is in Level Set mode. (See Site Options)
Common Lobby
If ‘Yes’, this will automatically prioritise the exit modes for each area:
(0 = Timed, 1 = Final Door, 2 = Timed/Final Door, 3 = PTS). This option is only relevant when Final Door option is used
on a system with different areas using a common lobby.
E.g. If Area C is selected as the ‘Final Door’ setting mode and the rest of the areas are selected as ‘Timed’, then
because ‘Final Door’ is higher priority, the users of every individual area must follow the ‘Final Door’ route to the
exit - making this door a ‘common for all areas’. If set to ‘NO’ the exit modes will be individually programmable to
each area.
Flexi Unset
When enabled, this setting will allow users to select which areas they unset (from the areas that they have been
permitted to unset.)
2 Key HU:
If the 1 and 7 keys are pressed and held together for a period of time (programmed in the keypad menu), a ‘Hold
Up’ will occur.
If ‘NONE’, the keys are disabled. If ‘SILENT’, a ‘Silent Hold Up’ will be signaled. If ‘Bells Only’, any external sounder will
activate but NO signals will be sent. If ‘BOTH’, any external sounder will activate and a signal will be sent using a Digi
1200 (PSTN),Digi-1200/Voice Digi GPRS, Digi LAN or Digi Wi-Fi module.
Tag Opens Doors
This function is only be used in conjunction with a reader being programmed as ‘Entry Control’ is in ‘ASSIGN
KEYPADS/READERS’.
If ‘YES’ the ‘Entry Control’ readers will control the setting/unsetting and the doors. If ‘NO’ the Entry Control readers
will control the setting/unsetting only.
Fire Key Enable
If ‘YES’ the fire key will be enabled on the Enforcer keypad.
Set With Polling Fault
If ‘YES’ the Enforcer will set the system if there is a wireless polling fault.
If ‘NO’ the user will not be able to set the Enforcer with a polling fault. The Enforcer will display a fault and the arming
procedure will be stopped. The input causing the poll fault can be identified in the event log.