![Heyer iTernIS ADV Operator'S Manual Download Page 189](http://html1.mh-extra.com/html/heyer/iternis-adv/iternis-adv_operators-manual_2128282189.webp)
Cleaning and maintenance |
iTernIS ADV
16.
7
Consult the maintenance recommendations in the manufacturer usage instructions
regarding the periodicity for replacing the filter unit. The ventilator should not venti
-
late when the air filter is not in optimal conditions.
It is also recommended to take the following cautions in order to ensure the proper
working of the filter:
• Always keep the device in an upright position.
• If necessary, use a hose connected to the drain outlet in order to collect the con
-
densation water in a bowl. Take care that the hose dimensions are correct. An
excessive length may increase the drain resistance unnecessarily.
• If a water-catcher hose is used, check to see that this does not stretch in an
upward direction, as this may hinder the drainage.
The fuse box is found near the main power source input. Located in the rear panel
are two F 2L 250V fuses (Ø 5 mm x 20 mm - 250 V / 2 A). In the case of their repla-
cement being necessary, use fuses of the same characteristics.
Fig. 16-3
Relative loca-
tion of the fuse box (A)
in relation to the main
electric power source
input (B).
The scheduled maintenance is performed every 5000 hours of usage, or every
year, whichever comes first. This is a procedure performed in the factory or by an
authorized service technician.
When the computer is sent out for maintenance, include a note explaining the aty-
pical events which may have occurred. Thus, the assessments will also take these
peculiarities into consideration.
When the 5000 hours of usage are met, the necessity to perform this maintenance
is alerted by an icon, which will appear on the upper right-hand side of the screen.
This icon will be deleted by the service technician once the maintenance protocol
has finished, and will appear again after another 5000 hrs of usage, or after one
year has elapsed since the last service.
The following list summarizes the verification of parts, accessories and consuma
-
bles which are executed during a scheduled maintenance of the equipment.
• Expiratory set
16.3.4 |
Scheduled Maintenance
(every 5000 hours or ever
year)
16.3.3 |
Fuses
Summary of Contents for iTernIS ADV
Page 1: ...Operator s Manual Rev 1 0 07 2011 INNOVATIONS AS A SERVICE TO THE PATIENT ...
Page 2: ......
Page 3: ...User s Instruction Manual Rev 1 0 07 2011 ...
Page 10: ...User Instruction Manual iTernIS ADV vi This Page Left Intentionally Blank ...
Page 12: ...Introduction iTernIS ADV 1 2 This Page Left Intentionally Blank ...
Page 20: ...Warnings Precautions Notes iTernIS ADV 2 2 This Page Left Intentionally Blank ...
Page 24: ...Warnings Precautions Notes iTernIS ADV 2 6 This Page Left Intentionally Blank ...
Page 26: ...Assembly and installation iTernIS ADV 3 2 This Page Left Intentionally Blank ...
Page 50: ...Start up and initial calibration iTernIS ADV 5 2 This Page Left Intentionally Blank ...
Page 60: ...Start up and initial calibration iTernIS ADV 5 12 This Page Left Intentionally Blank ...
Page 62: ...Basic operations iTernIS ADV 6 2 This Page Left Intentionally Blank ...
Page 74: ...Basic operations iTernIS ADV 6 14 This Page Left Intentionally Blank ...
Page 76: ...Menu iTernIS ADV 7 2 This Page Left Intentionally Blank ...
Page 92: ...Menu iTernIS ADV 7 18 This Page Left Intentionally Blank ...
Page 94: ...Graphics management iTernIS ADV 8 2 This Page Left Intentionally Blank ...
Page 100: ...Graphics management iTernIS ADV 8 8 This Page Left Intentionally Blank ...
Page 102: ...ADL PED Operative modes iTernIS ADV 9 2 This Page Left Intentionally Blank ...
Page 120: ...ADL PED Operative modes iTernIS ADV 9 20 This Page Left Intentionally Blank ...
Page 122: ...NEO INF Operative modes iTernIS ADV 10 2 This Page Left Intentionally Blank ...
Page 136: ...NEO INF Operative modes iTernIS ADV 10 16 This Page Left Intentionally Blank ...
Page 138: ...Alarms iTernIS ADV 11 2 This Page Left Intentionally Blank ...
Page 148: ...Alarms iTernIS ADV 11 12 This Page Left Intentionally Blank ...
Page 150: ...Respiratory mechanics iTernIS ADV 12 2 This Page Left Intentionally Blank ...
Page 162: ...Respiratory mechanics iTernIS ADV 12 14 Fig 12 8 VD VT physiologic test screen ...
Page 164: ...Trends iTernIS ADV 13 2 This Page Left Intentionally Blank ...
Page 168: ...Trends iTernIS ADV 13 6 This Page Left Intentionally Blank ...
Page 170: ...Capnography iTernIS ADV 14 2 This Page Left Intentionally Blank ...
Page 176: ...Capnography iTernIS ADV 14 8 This Page Left Intentionally Blank ...
Page 178: ...Operational verification iTernIS ADV 15 2 This Page Left Intentionally Blank ...
Page 182: ...Operational verification iTernIS ADV 15 6 This Page Left Intentionally Blank ...
Page 184: ...Cleaning and maintenance iTernIS ADV 16 2 This Page Left Intentionally Blank ...
Page 192: ...Technical specifications iTernIS ADV 17 2 This Page Left Intentionally Blank ...
Page 205: ...Appendices iTernIS ADV A i Appendices Chapter Contents A I Troubleshootings ...
Page 206: ...Appendices iTernIS ADV A ii This Page Left Intentionally Blank ...
Page 212: ...Warranty iTernIS ADV G ii This Page Left Intentionally Blank ...
Page 215: ...Alphabetical index iTernIS ADV I iii W Watchdog 17 9 WOBi 7 3 Y Y connector or part 3 8 ...
Page 216: ...Alphabetical index iTernIS ADV I iv This Page Left Intentionally Blank ...
Page 217: ......
Page 218: ......