Installing the replacement chassis
CAUTION:
Lift the library from the side edges. Lifting the library from the magazine or tape drive openings can
damage the library.
Procedure
1.
Remove and store the shipping lock.
NOTE:
Skip this step for the MSL8048 and MSL8096.
The shipping lock prevents the robotic transport mechanism from moving during shipment. Remove the
shipping lock before powering on the library. The shipping lock is held in place with a piece of tape and is
located in the top center of the new chassis. After the shipping lock is removed, it should be stored on the
back panel of the chassis for future use.
a.
Locate the tape and lock at the top of the chassis.
Figure 106: Shipping lock location
b.
Remove the tape, then remove the lock.
c.
Store the lock on the back panel of the library.
230
Installing the replacement chassis