Event code
Description
Details and Solution
63
Invalid cartridge. Drive has rejected the
cartridge as invalid.
• Verify that the cartridge generation and
technology are supported by the device.
See
on page 47.
• Retry the operation.
• If problems persist, exchange the data
cartridge.
64
Invalid cleaning cartridge. Drive has rejected
the cartridge as invalid.
65
Invalid upgrade cartridge. Drive has rejected
the cartridge as invalid.
• Retry the operation.
• If problems persist, exchange the data
cartridge.
66
Diagnostic tape write protect.
The diagnostic test needs to write data but
the tape being used for the test is write
protected. Ensure that the device has a tape
that is not write protected for use during the
diagnostic test.
67
Incompatible medium
The drive tried to read or write data from a
tape from an incompatible LTO generation.
70
SCSI message error
Check the SCSI cable connection and verify
that the maximum cable length is not
exceeded. Verify that the SCSI bus is
properly terminated.
71
SCSI parity error
72
SCSI invalid message
73
SCSI: overlapped command attempt
The application software made an illegal
request.
74
SCSI: echo buffer overwritten
75
Download prevented — barcode reader
hardware requires newer code revision.
Update the library to the most current
firmware version.
76
Destination element unexpectedly full.
This can happen if a cartridge is moved
without the library completing a full
inventory. Rescan the tapes from the RMI or
OCP.
77
Download prevented because of an
incompatible library controller.
Update the library to the most current
firmware version.
78
Download prevented because of
incompatible robot firmware.
Update the libraryto the most current
firmware version.
7B
Invalid firmware version. Only signed
firmware images are allowed.
The library will only accept signed firmware
images. Download a signed firmware image.
Table Continued
Troubleshooting information and procedures
203