T-CONTROL
9
35
Term
Description
Unit
Motor protection
Discharge
Display of the status of the motor protection discharge: If the control
lamp is lit, the discharge motor protection input has triggered.
-
End switch room
discharge
Display of the status of the end switch room discharge: If the control
lamp is lit, the end switch room discharge input has triggered.
-
Discharge
Display of the status of the discharge:
If switch on green
➔
Output active.
-
Release Stoker screw
Indicates the state of the grate cleaning:
If switch on green
➔
Output active.
-
In- / Outputs
1
2
3 4 5 6 7
Sensor
Zeropoint
/
Position
Indicates the state of the Sensor Zeropoint / Position:
If the control lamp lights up, the sensor zero point / position input is
active.
-
Motor
counter
clockwise / clockwise
Indicates the state of the motor counter clockwise / clockwise:
If switch on green
➔
Output active.
-
Stoker screw
Indicates the state of the stoker screw
If switch on green
➔
Output active.
-
Tank empty
Displays the condition of the hopper.
If the indicator lamp lights up, the hooper is empty.
-
Container screw
Displays the condition of the container screw:
If switch on green
➔
Output active.
-
Pellet sucker
Displays the condition of the pellet sucker:
If switch on green
➔
Output active.
-
Vacutrans flap opened
Indicates the status of the vacutrans flap.
If the indicator lamp lights up, the input of the vacutrans flap is active.
-
In- / Outputs
1 2
3
4 5 6 7
Motor protection
Discharge ½
Display of the status of the motor protection discharge: If the control
lamp is lit, the discharge motor protection input has triggered.
-
End switch room
discharge ½
Display of the status of the end switch room discharge: If the control
lamp is lit, the end switch room discharge input has triggered.
-
Discharge ½
Display of the status of the discharge:
If switch on green
➔
Output active.
-
Vacutrans flap ½
opened
Indicates the status of the vacutrans flap:
If switch on green
➔
Output active.
-
Pellet sucker ½
Displays the condition of the pellet sucker 1:
If switch on green
➔
Output active.
-
Door Storage room
open
Display of the status of the door storage room: If the control lamp is lit,
the input of the door storage room has triggered.
-
Agitator
Displays the condition of the agitator:
If switch on green
➔
Output active.
-
In- / Outputs
1 2 3
4
5 6 7
Ignition element /
ignition heating / fan
Display the state of the Ignition element (ignition heating / fan):
If switch on green
➔
Output active.
-
Lambda probe heating
Indicates the state of the lambda probe heating.
If switch on green
➔
Output active.
%
ID fan
Display of the output of the ID-fan control and display of the currently
measured speed.
%
Under pressure
Indication of the under pressure in the combustion chamber (at under
pressure control or monitoring)
Pa
Secondary air flap
Indication of the secondary air flap control output
%
Primary air fan
Indication of the primary air fan output
%
Summary of Contents for pelletstar CONDENSATION 10
Page 1: ...OPERATING INSTRUCTIONS Pellet boiler pelletstar CONDENSATION 10 60 ...
Page 86: ...15 Annex 86 Hydraulic recommendation 2 ...
Page 87: ...Annex 15 87 15 2 Solar module schematic representation Program 1 ...
Page 88: ...15 Annex 88 Program 2 ...
Page 89: ...Annex 15 89 Program 3 ...
Page 90: ...15 Annex 90 Program 4 ...
Page 91: ...Annex 15 91 Program 5 ...
Page 92: ...15 Annex 92 Program 6 ...
Page 93: ...Notes 16 93 16 NOTES ...