PEL-3000(H) User Manual
180
Load On/Off Status
Description
Pin 13 (Load On Status) of the J1 connector is used
to monitor the load status (on or off).
Pin out
The Load On Status pin
is a photo-coupled open-
collector output.
17
13
Photocoupler input: 30V max, 8mA, max.
External Control of the Range
Description
The range for the present operating mode can be
externally controlled when the current range is set
to high range.
The range is changed using pins 8, 9 (Range Cont 1
&2) and 12 (A Com) of the J1 connector.
When externally controlling the range, the pin
input combination determines which range is
chosen.
Note
1.
Press
Main
> Configure [F5] > Next Menu
[F4] > External [F3] and set the Control setting
to V, R or Riv to enable external control.
2.
When externally controlling the range, the pin
input combination determines which range is
chosen.
I Range
Pin 9
Pin 8
H
High
High
M
High
Low
L
Low
High
Summary of Contents for PEL-3000 Series
Page 1: ...DC Electronic Load PEL 3000 H Series USER MANUAL VERSION 2 00 ISO 9001 CERTIFIED MANUFACTURER ...
Page 24: ...PEL 3000 H User Manual 22 PEL 3111H PEL 3211 Booster Pack PEL 3211H Booster Pack ...
Page 41: ...GETTING STARTED 39 Fasteners 2 ...
Page 207: ...REMOTE CONTROL 205 6 7 8 9 The function check is complete ...
Page 229: ...APPENDIX 227 Operating Area PEL 3021 ...
Page 230: ...PEL 3000 H User Manual 228 PEL 3041 ...
Page 231: ...APPENDIX 229 PEL 3111 ...
Page 232: ...PEL 3000 H User Manual 230 PEL 3211 Booster Pack PEL 3021H ...
Page 233: ...APPENDIX 231 PEL 3041H ...
Page 234: ...PEL 3000 H User Manual 232 PEL 3111H PEL 3211H Booster Pack ...
Page 235: ...APPENDIX 233 ...