FUNCTION MENU
115
Complete Ring Time
Description
The Complete Ring Time function turns the alarm
on for a user-set amount of time after a program,
sequence or OCP function has finished.
Function Select
Screen
Program
Fast
Sequence
PROG
RS232
01/Oct/2018
Normal
Sequence
OCP
Function Select
FUNCTION
Complete Ring Time
NSEQ Timer
Elapsed
5 s
PROG
Operation
1.
Press
FUNC
.
2.
Select
Complete Ring Time
and select how long
the alarm should ring after a function has
completed.
Range
Default
OFF, 1 ~ 600s, Infinity
Off
The Complete Ring Time setting applies to all
the functions.
Note
The alarm may not sound if Alarm Tone is turned off
in the Utility>Other menu. See page 92 for setting
details.