FUNCTION MENU
149
Results:
Power Source
OCP tripped
OCP
RS232
01/Oct/2018
OCP Test
7.498
V
0.0000
A
0.00
W
Set Curr:
Fetch Volt:
2.000
1.500
1.000
6.91
6.92
6.91
Indicating power supply
OCP was tripped.
Current
:
Step current setting on the load
when the power supply
’
s OCP
was tripped.
2.500A
The OCP Test will return the current setting of the
last step when the power supply’s OCP was
tripped.
Power Source
OCP time out
OCP
RS232
01/Oct/2018
OCP Test
7.498
V
0.0000
A
0.00
W
Set Curr:
Fetch Volt:
2.000
1.500
1.000
6.91
6.92
6.91
OCP time out
OCP time out indicates that the
power supply OCP was not
tripped.
OCP time out will occur if the power supply’s OCP
fails to trigger. This is determined when the
measured voltage is less than Trig V and the
measured current is greater than End C.
Summary of Contents for PEL-3000 Series
Page 1: ...DC Electronic Load PEL 3000 H Series USER MANUAL VERSION 2 00 ISO 9001 CERTIFIED MANUFACTURER ...
Page 24: ...PEL 3000 H User Manual 22 PEL 3111H PEL 3211 Booster Pack PEL 3211H Booster Pack ...
Page 41: ...GETTING STARTED 39 Fasteners 2 ...
Page 207: ...REMOTE CONTROL 205 6 7 8 9 The function check is complete ...
Page 229: ...APPENDIX 227 Operating Area PEL 3021 ...
Page 230: ...PEL 3000 H User Manual 228 PEL 3041 ...
Page 231: ...APPENDIX 229 PEL 3111 ...
Page 232: ...PEL 3000 H User Manual 230 PEL 3211 Booster Pack PEL 3021H ...
Page 233: ...APPENDIX 231 PEL 3041H ...
Page 234: ...PEL 3000 H User Manual 232 PEL 3111H PEL 3211H Booster Pack ...
Page 235: ...APPENDIX 233 ...