PEL-3000(H) User Manual
206
F
AQ
•
The load voltage indicated on the load module is below expected.
•
The front panel keys are not working.
•
The load won’t turn on.
•
The performance does not match the specification
The load voltage indicated on the load module is below expected.
Ensure the load leads are as short as possible, twisted and use the
appropriate wire gauge. Ensure that voltage sense is used, this can
help alleviate the voltage drop across the load the leads.
The front panel keys are not working.
Check to make sure that the key lock has not been activated. LOCK
will be shown on the panel when the screen is locked. Press Shift +
Lock to unlock the keys.
The load won’t turn on.
If you are using the load key to try to turn the load on and the load
won’t turn on, it is possible that external control is activated and
that the LoadOn In setting is set to low. See page 177 for details.
The performance does not match the specification.
Make sure the device is powered On for at least 30 minutes, within
+20°C-+30°C. This is necessary to stabilize the unit to match the
specification.
Summary of Contents for PEL-3000 Series
Page 1: ...DC Electronic Load PEL 3000 H Series USER MANUAL VERSION 2 00 ISO 9001 CERTIFIED MANUFACTURER ...
Page 24: ...PEL 3000 H User Manual 22 PEL 3111H PEL 3211 Booster Pack PEL 3211H Booster Pack ...
Page 41: ...GETTING STARTED 39 Fasteners 2 ...
Page 207: ...REMOTE CONTROL 205 6 7 8 9 The function check is complete ...
Page 229: ...APPENDIX 227 Operating Area PEL 3021 ...
Page 230: ...PEL 3000 H User Manual 228 PEL 3041 ...
Page 231: ...APPENDIX 229 PEL 3111 ...
Page 232: ...PEL 3000 H User Manual 230 PEL 3211 Booster Pack PEL 3021H ...
Page 233: ...APPENDIX 231 PEL 3041H ...
Page 234: ...PEL 3000 H User Manual 232 PEL 3111H PEL 3211H Booster Pack ...
Page 235: ...APPENDIX 233 ...