SERVICE CALL CONDITIONS
Rev. 9/2001
A294/A295
7-8
SM
SC322: Laser Synchronization Error
Definition [B’]
The laser synchronization signal cannot be detected from the synchronization
detector even if the laser diodes are activated.
Possible Causes
•
Poor connection between the laser synchronization detector and the LDB
•
Laser synchronization detector out of position
•
Laser synchronization detector defective
•
LDB defective
•
SICU defective
•
Front door safety switches defective
SC323: Excessive LD Drive Current
Definition [B’]
The LDB applies more than 110 mA to the LD.
Possible Causes
•
LDB defective (not enough power, due to aging)
•
Poor connection between the LDB and the SICU board
•
High temperature of LD on LDB
SC335: Polygonal Mirror Motor Error 1
Definition [B]
The polygonal mirror motor does not reach its operating speed within 20
seconds after the polygonal mirror motor turns on, or the polygonal mirror
motor speed is changed.
Possible Causes
•
Polygonal mirror motor defective
•
Poor connection between the polygonal mirror motor drive board and the
SICU board
•
Polygonal mirror motor drive board defective
•
SICU board defective
SC336: Polygonal Mirror Motor Error 2
Definition [B]
The SICU does not receive the stop signal from the polygonal mirror motor for
more than 20 seconds after the polygonal mirror motor turns off.
Possible Causes
•
Polygonal mirror motor defective
•
Poor connection between the polygonal mirror motor drive board and the
SICU board
•
Polygonal mirror motor drive board defective
•
SICU board defective
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Summary of Contents for A294
Page 2: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 3: ...A294 A295 SERVICE MANUAL RICOH GROUP COMPANIES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 4: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 5: ...A294 A295 SERVICE MANUAL 000902MIU C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 6: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 8: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 10: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 12: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 26: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 27: ...OVERALL INFORMATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 28: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 49: ...DETAILED DESCRIPTIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 50: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 180: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 181: ...INSTALLATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 182: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 221: ...SERVICE TABLES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 222: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 230: ...SERVICE PROGRAM MODE Rev 9 2001 SM 4 8 A294 A295 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 323: ...PREVENTIVE MAINTENANCE C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 324: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 329: ...REPLACEMENT AND ADJUSTMENT C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 330: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 457: ...TROUBLESHOOTING C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 458: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 516: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 517: ...3 000 SHEET FINISHER B302 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 518: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 554: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 555: ...LARGE CAPACITY TRAY B303 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 556: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 578: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 579: ...A3 DLT TRAY KIT B331 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 580: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 585: ...DIFFERENCES FROM THE A294 I A295 I MODELS C PIA N O CONTROLADA C PIA N O CONTROLADA...