BLOWN FUSE CONDITIONS
Rev. 9/2001
A294/A295
7-42
SM
7.3 BLOWN FUSE CONDITIONS
Fuses are not used for the output lines from the PSU. An electronic current cut-off
method is used instead.
The PSU consists of three converters; 1st converter, 2nd converter, and Energy
saver converter. Each converter has an LED which indicates the status of the
converter.
LED No.
LED 1
LED 2
LED 3
Converter
Energy saver
1st Converter
2nd Converter
Output
Vcc1
Vcc2, Vmm
Vaa, Vca, Vcb
In Stand-by Condition
On
On
On
In Energy Saver Mode
On
Off
Off
LED status when a converter is defective
Energy saver
Off
Off
Off
1st
On
Off
Off
2nd
On
On
Off
When the 1st converter is defective, the output of the 2nd converter is also
stopped. When the energy saver converter is defective, all the outputs are stopped.
There is a circuit breaker CB1 on the PSU which cuts all the power from the PSU
when excess current flows.
Additionally, there is a fuse only for the AC input line of the energy saver converter.
Fuse
Symptom when turning on the main power switch
Power Supply Board
FU404
No response
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Summary of Contents for A294
Page 2: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 3: ...A294 A295 SERVICE MANUAL RICOH GROUP COMPANIES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 4: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 5: ...A294 A295 SERVICE MANUAL 000902MIU C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 6: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 8: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 10: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 12: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 26: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 27: ...OVERALL INFORMATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 28: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 49: ...DETAILED DESCRIPTIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 50: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 180: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 181: ...INSTALLATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 182: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 221: ...SERVICE TABLES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 222: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 230: ...SERVICE PROGRAM MODE Rev 9 2001 SM 4 8 A294 A295 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 323: ...PREVENTIVE MAINTENANCE C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 324: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 329: ...REPLACEMENT AND ADJUSTMENT C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 330: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 457: ...TROUBLESHOOTING C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 458: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 516: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 517: ...3 000 SHEET FINISHER B302 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 518: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 554: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 555: ...LARGE CAPACITY TRAY B303 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 556: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 578: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 579: ...A3 DLT TRAY KIT B331 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 580: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 585: ...DIFFERENCES FROM THE A294 I A295 I MODELS C PIA N O CONTROLADA C PIA N O CONTROLADA...