DRUM UNIT
A294/A295
2-40
SM
V
G
Adjustment
The potential on unexposed areas of the drum (V
D
) gradually changes during drum
life. To keep V
D
constant, the grid voltage (V
G
) is adjusted during process control
initial setting.
The BCU checks V
D
using the drum potential sensor [A]. If it is not within the target
range (–900 V
±
20 V), the BCU adjusts V
G
(Grid Voltage) through the
charge/bias/grid power pack to get the correct target voltage.
The most recently detected values can be displayed with SP3-902-2 (V
D
) and 3-
902-4 (V
G
).
If the CPU cannot get V
D
within the target range by changing V
G
, V
G
is set to the
value stored in SP2-001-01 and LD power is set to the value stored in SP2-103.
Then SC312, SC313, or SC315 is logged.
Charge/Bias/Grid
P . P
B C U
A294D642.WMF
[A]
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Summary of Contents for A294
Page 2: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 3: ...A294 A295 SERVICE MANUAL RICOH GROUP COMPANIES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 4: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 5: ...A294 A295 SERVICE MANUAL 000902MIU C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 6: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 8: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 10: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 12: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 26: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 27: ...OVERALL INFORMATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 28: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 49: ...DETAILED DESCRIPTIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 50: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 180: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 181: ...INSTALLATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 182: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 221: ...SERVICE TABLES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 222: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 230: ...SERVICE PROGRAM MODE Rev 9 2001 SM 4 8 A294 A295 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 323: ...PREVENTIVE MAINTENANCE C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 324: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 329: ...REPLACEMENT AND ADJUSTMENT C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 330: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 457: ...TROUBLESHOOTING C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 458: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 516: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 517: ...3 000 SHEET FINISHER B302 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 518: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 554: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 555: ...LARGE CAPACITY TRAY B303 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 556: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 578: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 579: ...A3 DLT TRAY KIT B331 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 580: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 585: ...DIFFERENCES FROM THE A294 I A295 I MODELS C PIA N O CONTROLADA C PIA N O CONTROLADA...