1.1. GENERAL DESCRIPTION
The SMOR system is a microprocessor based multifunction protection, control and measurement unit. The
SMOR uses a set of algorithms to create a general purpose protection and monitoring unit for power
systems.
The SMOR system is supplied in a 19’’ rack case 2 units high. Figure 1 shows a diagram for panel drilling
installation.
All the information and settings of the unit are accessible by means of a computer connected to the serial
port (RS232 or fiber-optic) or using the man-machine interface (MMI), which includes a 20 character keypad
and a two line liquid crystal display (LCD) with 16 character on each line, located on the front of the relay.
This protection system includes the following functions:
a) Protection:
•
6 overcurrent units arranged in the following way:
- 3 phase units:
- 51PT, Instantaneous, Inverse or definite time.
- 50PH, Instantaneous or definite time.
- 50PL, Instantaneous or definite time.
- 3 ground units:
- 51NT, Instantaneous, Inverse or definite time.
- 50NH, Instantaneous or definite time.
- 50NL, Instantaneous or definite time.
•
Independent directional supervision adjustment for each overcurrent functions.
•
Negative sequence overcurrent
•
Three-phase over and undervoltage
•
Ground overvoltage (2 levels). NOTE: Only for the SMOR7000 model an open delta input is available.
•
Over and under frequency
b) Monitoring and Register
•
Current measurement for each phase and ground.
•
Negative sequence current measurement.
•
Measurement of line to line voltages.
•
Measurement of active and reactive power along with power factor.
•
Frequency measurement.
•
Breaker status.
•
LED indicators - 17 LED display (16 of which can be configured by the user).
•
Breaker supervision for failure-to-open or failure-to-close (optional, mounted in the additional board).
•
Breaker health monitoring (
Σ
I2 t) per phase.
•
Phase rotation sequence selection (ABC or CBA).
•
Maximeter for current and active power.
•
Built in self-checking unit.
Summary of Contents for SMOR-B GEK 105593C
Page 5: ......
Page 9: ...GEK 105593C 4 ...
Page 25: ...GEK 105593C 20 FIGURE 5 RECLOSER STATES DIAGRAM 226B2200H1 SUMMARISED ...
Page 51: ...GEK 105593C 46 ...
Page 71: ...GEK 105593C 66 ...
Page 73: ...GEK 105593C 68 ...
Page 88: ...GEK 105593C 83 FIGURES FIGURES FIGURES FIGURES ...
Page 89: ...GEK 105593C 84 FIGURE 1 PANEL DRILLING DIMENSIONS FOR 19 RACK MODELS 226B6086H10 ...
Page 91: ...GEK 105593C 86 FIGURE 3 INVERSE CHARACTERISTIC OPERATING CURVE 226B7414H1 ...
Page 92: ...GEK 105593C 87 FIGURE 4 VERY INVERSE CHARACTERISTIC OPERATING CURVE 226B7414H2 ...
Page 93: ...GEK 105593C 88 FIGURE 5 EXTREMELY INVERSE CHARACTERISTIC OPERATING CURVE 226B7414H3 ...
Page 94: ...GEK 105593C 89 FIGURE 6 RECLOSER PROGRAM FLOWCHART 226B2200H1 ...
Page 95: ...GEK 105593C 90 FIGURE 7 FRONT VIEW FOR 19 RACK MODELS 226B7412H9 ...
Page 96: ...GEK 105593C 91 FIGURE 8 FRONT VIEW FOR 1 2 RACK MODELS ...
Page 97: ...GEK 105593C 92 FIGURE 9 EXTERNAL CONNECTIONS FOR 19 MODELS 189C4101H1 ...
Page 100: ...GEK 105593C 95 FIGURE 13 REAR VIEW FOR 19 MODELS 226B7412H10 ...
Page 102: ...GEK 105593C 97 FIGURE 15 DIMENSIONS DIAGRAM FOR 19 MODELS 226B6086H10 ...