Location
Term
Definition
2.4.4.1 Partition
Reports
A menu option that specifies the events that are enabled
for each partition. Events specified in this option are related
to all partitions in the system.
2.4.4.1.1 Opening/Closing
A menu option that enables opening/closings reporting.
2.4.4.1.2 Zone
Bypass
A menu option that that sends a report to the central
station when zones are bypassed.
2.4.4.1.3 Zone
Restore
A menu option that sends a report to the central station
when zones are restored.
2.4.4.1.4 Zone
Trouble
A menu option that sends a report to the central station
when a zone fault condition occurs.
2.4.4.1.5 Zone
Tamper
A menu option that sends a report to the central station
when a zone tamper occurs.
2.4.4.1.6 Cancel
A menu option that enables cancel reporting. A cancel
report is sent to the central station when the system is
disarmed (within the time specified by the dialer delay)
after an alarm.
2.4.4.1.7 Recent
Closing
A menu option that sends a report to the central station if
an alarm occurs within five minutes after the panel has
been armed. The user number that armed the system is
also sent.
2.4.4.1.8 Exit
Error
A menu option that specifies that the control panel sends
an exit error report if an entry/exit zone is faulted when the
exit delay expires. This report is sent along with the user
number that armed the system, if the panel is not disarmed
before the entry delay expires. The alarm report is also
sent. Even if this feature is not enabled, the siren sounds if
any entry/exit zone is faulted when the exit delay expires.
2.4.4.2 System
Reports
A menu entry that groups options relating to system
reports.
2.4.4.2.1 Tamper/Fault
A
menu entry that groups together the tamper and fault
events that are reported to the central station.
2.4.4.2.1.1 Box
Tamper
A menu option that enables the box tamper switch on the
control panel. The control panel has an input for a normally
closed tamper switch. When opened, a box tamper is
reported as an event.
2.4.4.2.1.2 Expander
Trouble
A menu option that sends a report to the central station
when an expander fault condition occurs.
2.4.4.2.1.3 Siren
Supervision
A menu option that monitors the siren to detect cut wires. If
the wires are cut, the control panel sends a report to the
central station.
2.4.4.2.1.4
RF Sensor Lost
A menu option that sends a report to the central station,
when an RF sensor is missing.
RF sensors send out supervision signals every 15 or 64
minutes, depending on the frequency. An RF receiver must
receive these signals within a specified time window. This
window is set by the Supervision timer. If the RF receiver
does not receive these signals during the time window, the
RF sensor is considered missing.