NX-10 Installers manual
153
2.
Select
Program KP Text,
press
OK
, and then select a language using the
½¾
keys.
3.
Scroll to
Zones/Messages>Custom Message
, press
OK
, and then edit the appropriate line
of the message.
4.
Press
OK
. The keypad beeps once to accept the change and returns to
Custom Message
.
Edit the other line of the message, if required.
Setting the keypad partition and keypad number
When you first power up the keypad, you are prompted to set the language, the default country and
the partition and keypad number for the current keypad. The keypad can connect to the bus only after
you set these numbers. The partition number and keypad number prompts are displayed for the initial
setting only. To change these numbers again, scroll to
This Keypad>Partition Number
and
This
Keypad>Keypad Number.
Setting the exit buzzer options
You can configure a behaviour of the warning signal emitted during the exit delay, when the user is
leaving premises. The menu entries responsible for the keypad buzzer are partially located in the
Partition Settings
and
System Settings
groups of the
Control Panel
menu. These settings affect all the
keypads in the system or all the keypads in the partition. For example to cancel the keypad exit
buzzer completely for all the keypads:
1.
Navigate with the
½¾
keys to
Control Panel
and press
OK
.
2.
Scroll to
System Settings>Feature Select>Miscellaneous>Silent Exit Always
.
3.
Use the
½¾
keys to change the status to
Yes
and press
OK
.
4.
The keypad beeps once to accept the change and returns to
Silent Exit Always
.
You can also silence the particular keypad. The following options cancel the exit buzzer and chime
on the current keypad only:
1.
Navigate with the
½¾
keys to
This Keypad
and press
OK
.
2.
Select
Keypad Features>Silent Keypad
and press
OK
.
3.
Use the
½¾
keys to change the status to
Yes
and press
OK
.
4.
The keypad beeps once to accept the change and returns to
Silent Keypad
.
To set advanced buzzer options for the keypad on partition 1, when exit delays are set to 20 seconds
and 10 seconds respectively:
1.
Navigate with the
½¾
keys to
Control Panel
and press
OK
.
2.
Scroll to
Partition Settings>Partition 1>Timers>Exit Time 1
and press
OK
.
3.
Type
20
and press
OK
.
4.
The keypad beeps once to accept the change and returns to
Exit Time 1
.
5.
Scroll to
Partition Settings>Partition 1>Timers>Exit Time 2
and press
OK
.
6.
Type
10
and press
OK
.
7.
The keypad beeps once to accept the change and returns to
Exit Time 2
.
8.
Navigate with the
½¾
keys to
This Keypad
and press
OK
.