Location
Term
Definition
2.4.4.2.1.5
RF Low Battery
A menu option that sends a report to the central station
when a low battery condition occurs in an RF sensor.
2.4.4.2.1.6 CleanMe
A menu option that sends a report to the central station
when a smoke detector is dirty.
2.4.4.2.2 Power
A menu entry that groups the power events that are
reported to the central station.
2.4.4.2.2.1 Mains
Failure
A menu option that sends a report to the central station
when the mains power supply fails. A delay time can be set
for this report.
2.4.4.2.2.2 Low
Battery
A menu option that enables low battery reporting on the
control panel.
2.4.4.2.2.3 Aux
Overcurrent
A menu option that enables overcurrent reporting. A report
is sent to the selected central station when too much
current is drawn from a device powered by the system.
2.4.4.2.3 Communications
A menu entry that groups together the communication
events that are reported to the central station.
2.4.4.2.3.1
Phone Line Cut
A menu option that sends a report is sent to the central
station the moment the phone line cut is restored.
2.4.4.2.3.2
Fail to Communicate
A menu option that sends a report to the central station
when the system has failed to communicate with the
central station after the number of attempts set in Dial
Attempts. The report is sent when communication with the
central station has been restored.
2.4.4.2.3.3 Autotest
A menu option that enables reporting of autotest events to
the central station at a specified interval.
2.4.4.2.3.4
Autotest only when Armed
A menu option that allows test calls to be made only when
the system is armed.
2.4.4.2.4.1 Log
Full
A menu option that sends a report to the central station
when the event log is full.
2.4.4.2.4.2 Start/End
Programming
A menu option that causes reports to be sent to a specified
phone number. A report is sent when local programming
begins and ends.
2.4.4.2.4.3 End
Download
A menu option that sends a report to the central station
when downloading from the up/download software to the
control panel is complete.
2.4.4.2.5
Bypass on Force Arm
A menu option that enables bypass reporting when a zone
is force armed.
2.4.4.2.6
First to Open/Last to Close
A menu option that sends a report to the central station
stating when the system opened and closed. This option
can only be used in a multi-partitioned system.
A report is sent stating the first partition opened. A log is
then kept recording when the other partitions opened and
when they closed. This information is sent in a second
report when the last open partition closes.
2.4.4.3
Report Codes
A menu option that groups codes that are sent to the
central station when a particular event occurs.