NX-10 Installers manual
115
LOCATION 91 - PARTITION 2 ENTRY EXIT TIMERS (6 segments, numerical data)
Location 91 is used to enter the entry and exit times, in seconds. There are 2 separate entry and exit
times. Valid entries are 10-255 seconds. If all the segments are “0”, the entry and exit times for
partition 1 will be used.
Segment 1
Entry time 1
Entry time that will be used when a delay 1 zone type
initiates an entry delay
Segment 2
Exit time 1
Exit time that will be used for all zones designated as delay 1
Segment 3
Entry time 2
Entry time that will be used when a delay 2 zone type
initiates an entry delay
Segment 4
Exit time 2
Exit time that will be used for all zones designated as delay 2
Segment 5
Reserved
Segment 6
Reserved
LOCATION 92 - ACCOUNT CODE FOR PARTITION 3 (6 segments, numerical data)
The account code that is sent when reporting partition 3 is programmed in location 92. If location 92
is left unprogrammed (all “10”), then the account code corresponding to the phone number that is
dialled will be used. If the account code is less than six digits, program a “10” in the segment
immediately after the last digit of the account code. If the account code is 6 digits long, program all 6
segments.
LOCATION 93 - PARTITION 3 FEATURE AND REPORTING SELECTIONS (5 segments, feature
selection data)
Location 93 is used to enable certain features that the user can access or see from the keypad of the
system. In addition, certain communicator reports are enabled in this location. Each of these features
can be enabled by partition. This location contains 5 segments, with eight possible features per
segment. Refer to location 23 for the feature selections. If all the segments are blank (nothing
enabled), the features for partition 1 will be used.
LOCATION 94 - PARTITION 3 ENTRY EXIT TIMERS (6 segments, numerical data)
Location 94 is used to enter the entry and exit times, in seconds. There are 2 separate entry and exit
times. Valid entries are 10-255 seconds. If all the segments are “0”, the entry and exit times for
partition 1 will be used.
Segment 1
Entry time 1
Entry time that will be used when a delay 1 zone type
initiates an entry delay
Segment 2
Exit time 1
Exit time that will be used for all zones designated as delay 1
Segment 3
Entry time 2
Entry time that will be used when a delay 2 zone type
initiates an entry delay
Segment 4
Exit time 2
Exit time that will be used for all zones designated as delay 2
Segment 5
Reserved
Segment 6
Reserved