NX-10 Installers manual
79
Location
Term
Definition
2.4.4.3.6.6 End
Download
A menu entry that groups the report codes sent to the
central station when downloading is complete.
2.4.5 Custom
Format
A menu option that allows you to build communication
formats if using a non-standard central station. Consult
technical support before using this option and the related
options.
2.4.5.1
Features 1
A menu option that allows you to configure your own
reporting protocol based on the options enabled. Consult
technical support before using this option and the related
options.
2.4.5.2
Features 2
A menu option that allows you to configure your own
reporting protocol based on the options enabled. Consult
technical support before using this option and the related
options.
2.4.5.3
Inter-Digit Time
A menu option that sets the inter-digit time for custom
pulse format (time between output digits). The inter-digit
time is the value programmed on this location, divided by
the pulse-rate (PPS) of the programmed format. For
example, when the value 10 is programmed here and a
pulse format of 20 PPS is used, the inter-digit time is 10/20
= 0.5 sec. Consult technical support before using this
option and the related options.
2.5
Partition Settings
A menu entry that groups all partition settings. These
settings include partition features, partition timers and so
on.
2.5.1.1 Timers
A menu entry that groups timer options.
2.5.1.1.1
Entry Time 1
A menu option that sets the time within which the user
must disarm the partition before a full alarm occurs. This
time can be between 10 and 255 seconds.
2.5.1.1.2
Exit Time 1
A menu option that sets the time within which the user
must leave the protected zone after arming the partition
before a full alarm occurs. When arming in Away mode, the
keypad can beep to warn the user (see keypad menu
options), also
System Arming, Leave Now
screen displays
until the end of the exit delay time. This time can be
between 10 and 255 seconds.
2.5.1.1.3
Entry Time 2
A menu option that sets the time within which the user
must disarm the partition before a full alarm occurs. This
time can be between 10 and 255 seconds.
2.5.1.1.4
Exit Time 2
A menu option that sets the time within which the user
must leave the protected zone after arming the partition
before a full alarm occurs. When arming in Away mode, the
keypad can beep to warn the user (see keypad menu
options), also
System Arming, Leave Now
screen displays
until the end of the exit delay time. This time can be
between 10 and 255 seconds.
2.5.1.2 Feature
Select
A menu entry that groups all optional features relating to
partitions.
2.5.1.2.1 Arming
A menu entry that groups the arming characteristics of the
selected partition.