9.
Scroll to
Keypad Features>Advanced Options>Buzzer On Exit>Exit Time 1
.
10.
Use the
½¾
keys to change the status to enabled and press
OK
.
11.
The keypad beeps once to accept the change and returns to
Exit Time 1
.
12.
Scroll to
Keypad Features>Advanced Options>Buzzer On Exit>Exit Time 2
.
13.
Use the
½¾
keys to change the status to disabled and press
OK
.
14.
The keypad beeps once to accept the change and returns to
Exit Time 2
.
This setting will cancel the final confirmation beep at the end of the exit time, and cause the keypad
to beep slowly for the first 10 seconds and then to beep fast for the last 10 seconds of the exit delay
countdown.
Note:
This option works for the Arm Away mode only; for the Arm Stay mode the keypad is always silent.
The keypad buzzer behaviour depends on both
Buzzer On Exit>Exit Time 1
and
Buzzer On Exit>Exit
Time 2
settings, and is described in the following table:
Table 16. Behaviour of the keypad buzzer based on the Buzzer On Exit settings (example).
ET1 = 10 s
ET2 = 20 s
Expect
OFF
OFF
20 s slow beep + confirmation beep
OFF
ON
20 s slow beep
ON
OFF
10 s fast beep + confirmation beep
ON
ON
20 s slow beep + confirmation beep
ET1 = 20 s
ET2 = 10 s
Expect
OFF
OFF
20 s slow beep + confirmation beep
OFF
ON
10 s slow beep + confirmation beep
ON
OFF
10 s slow beep + 10s fast beep
ON
ON
20 s slow beep + confirmation beep
ET1 = 10 s
ET2 = 10 s
Expect
OFF
OFF
10 s slow beep + confirmation beep
OFF
ON
10 s slow beep
ON
OFF
10 s fast beep + confirmation beep
ON
ON
10 s slow beep + confirmation beep
Glossary
Location
Term
Definition
3 This
Keypad
A menu entry that groups the settings of the current
keypad. It allows resetting of the keypad, configuration of
keypad features and verification of software version and
models.
3.1 Keypad
Number
A menu option that sets the keypad number within the
partition. The keypad can be numbered from one to eight.
The selected number links to the module number reported
to the central station in the case of tampers or expansion
troubles.