zones for all these events), and
Code Entry
(it filters out users). For all other events this setting is
ignored.
Segment 3 - Time
Selects the amount of time an output will remain activated when an output triggers. If this location is
programmed as a zero, the output will follow the particular event.
LOCATION 71 - PROGRAMMING SPECIAL FUNCTIONS AND PARTITIONS FOR OUTPUT 1 (2
segments, feature selection data)
Segment 1 - selects the following special conditions
Option
Function
ON
If output should time in minutes
1
OFF
If output times in seconds
ON
Output “Latch”: should latch until a code is entered
2
OFF Output
is
timed
ON
Timed or output should be reset if a code is entered while it is being timed
3
OFF
Stays timed (not reset) after code is entered
8
Reserved
Segment 2 - selects the following partitions
Option
Function
1
ON
If the event should activate when it occurs in partition 1
2
ON
If the event should activate when it occurs in partition 2
3
ON
If the event should activate when it occurs in partition 3
4
ON
If the event should activate when it occurs in partition 4
LOCATION 72 - PROGRAMMING THE X-10 LOCATION FOR OUTPUT 1 (2 segments, numerical
data)
Segment 1 - Unit code
Program a number from 0-15 to represent the corresponding X-10 unit code from the following table.
Module
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Segm 1
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15