7.
Navigate with the
½¾
keys to
Schedule Times>Closing/Autoarm
>
Hour
and press
OK
.
8.
Enter
18
and press
OK
.
9.
The keypad beeps once to confirm the change and returns to
Hour
.
10.
Scroll to
Minute
and press
OK
.
11.
Enter
0
and press
OK
.
12.
The keypad beeps once to confirm the change and returns to
Minute
.
Glossary
Location
Term
Definition
2 Control
Panel
This groups all options relating to the central processing
unit of the alarm system. The control panel monitors the
detection devices and activates any number of signalling
devices.
2.1 Inputs
A menu entry that groups options relating to all zones.
2.1.1 Zones
A menu entry that groups zone options.
2.1.1.1.1 Zone
Type
A menu option that specifies the zone type of a particular
zone.
2.1.1.1.2 Zone
Name
A menu option that allows the installer to define names for
each installed zone. For example, Zone 1 can be named
Living Room PIR.
2.1.1.1.3 Partitions
A menu entry that lists the partitions assigned to the
selected zone. The selected zone can trigger an event on
these partitions.
A zone may reside in any combination of partitions. A zone
that resides in more than one partition becomes a
common zone and is reported to its lowest partition
number. A common zone is armed only when all the
partitions that it belongs to are armed. It is disarmed the
moment one of the partitions it belongs to is disarmed.
2.1.1.1.4
Copy Zone
A menu option that copies the settings for an individual
zone to a contiguous set of other zones.
2.1.2 Swinger
Count
A zone characteristic that includes the selected zone in the
swinger counter for an partition. Each partition has a
swinger counter, and every zone trip in that partition
increments the swinger count for that partition. When the
count reaches the programmed number of trips, the panel
bypasses the last tripped zone and clears the counter.
An
Inputs
menu entry that contains the swinger count.
2.1.3 Zone
Types
A menu entry that groups zone type characteristics and
allows the installer to select a pre-defined zone type. There
are 30 pre-defined zone types. The characteristics of each
zone can be changed. For example, if a keypad beeps, if
the zone is a delay 1 or delay 2 zone, a 24-hour zone and
so on.
2.1.3.1.1 Input
Type
A menu entry that groups options that determine the basic
features of the selected zone type.
2.1.3.1.1.1 Fire
A zone type that reports a fire alarm when activated.