NX-10 Installers manual
223
Chapter B7
Enrolling modules
Figure 25. Enrol menu
To enrol and default the system modules, you must enable the advanced menu. Select
Maintenance
Mode>Advanced Menu>Enabled
and press
OK
.
Enrolling the system modules
When you select the enrol modules process, new modules are enrolled on both the control panel and
the keypad. The keypad must enrol modules in order to display the relevant menu options.
1.
Press
OK
at the system prompt and enter your installer code.
2.
Navigate with the
½¾
keys to
Enrol Modules>Enrol
and press
OK
.
3.
The keypad starts enrolling the modules. The
Enrolling
message is displayed while
enrolment is taking place (approximately 12 seconds). When the modules have been
enrolled, a beep sounds and the message disappears.
4.
When the modules have been enrolled, the keypad returns to
Enrol
.
5.
Verify the enrolled modules. Navigate with the
½¾
keys to
Maintenance Mode
and press
OK
.
6.
Scroll to
Log Review
and press
OK
. When the control panel enrols a module, it adds an
enrol event to the event log. This event contains the module number. Scroll through the
event log to verify that each module has been enrolled.
Note:
The modules are enrolled each time you leave programming mode. In this case, the Enrolling message is
displayed but no beep sounds.
Defaulting the modules
Each module can be defaulted. It is recommended that you default each module before modifying its
settings.
1.
Navigate with the
½¾
keys to
Reset Settings
in the relevant module menu and press
OK
.
In this case, select
Control Panel>Reset Settings
to restore the default control panel
settings.
2.
A confirmation message is displayed. Press
OK
to accept the default settings.
3.
The keypad sounder beeps once to confirm the reset.
1.1
Enrol
Number of Modules
1.2