Instruction Manual

1

PARTS DESCRIPTION

PA-5312E

(Wide angle protection : 40ft [12m])

PA-5325E

(Vertical curtain protection : 82ft [25m])

PASSIVE INFRARED SENSOR

We appreciate your purchase of a TAKEX passive infrared sensor.  This sensor will provide long and dependable service when 
properly installed.  Please read this Instruction Manual carefully for correct and effective use.
Please Note : This sensor is designed to detect intrusion and to initiate an alarm ; it is not a burglary-preventing device. 
                       TAKEX is not responsible for damage, injury or losses caused by accident, theft, Acts of God (including inductive     
                       surge by lightning), abuse, misuse, abnormal usage, faulty installation or improper maintenance.

Wire lead

Arrow point

Base locking screw

Cover locking screw
(Silver)

Fixer

Sensor locking screw
(White)

Memory LED
(Inside-Yellow)

Alarm LED
(Inside-Red)

SENSOR UNIT

BASE UNIT

COVER SPACER

COVER

Cover locking 
lever

Area selector

Area set chart

Matching mark

Indicator

Arrow point

1

Head unit

Tamper switch

Base locking hole

Alarm LED(Red)

Mode selector

Memory LED
(Yellow)

Limit pin

Multi-parabolic mirror
(Wide angle type)

Accessories

Instruction manual

: 1 pc

COVER SPACER

: 1 pc

Self-tapping screw

(ø4 x 30)

: 2 pcs

Warning

If the following events occur, turn off the power of the unit 
immediately, and ask the place of purchase for repair. Failure to 
follow this may result in fire, electric shock, and/or malfunction.

G%8:60,-9:=8,7:/:=,9/:=>:@9/,=01:@9/
G

Liquid, such as water, and/or foreign material has entered the unit

G&30@94?3,>/01:=80/,9/:=/,8,20/;,=?>

Use the sensor lock to fix the sensor unit for operation.  This can 
prevent injuries, and/or damage to the unit if the unit falls, as well 
as prevent the sensor from being tampered.

Mount the unit on a solid ceiling or wall surfaces where 
reinforcement materials are used. If you mount the unit on 
non-wood materials of plaster board or concrete, securely mount it 
using anchors and mounting screws that match the wall materials. 
Unstable mounting may result in injury and/or property damage if 
the unit falls.

Do not disassemble or modify this device. This may cause a fire, 
electrical shock, or malfunction of the device.

Do not install this device in a location that cannot support its 
weight. This may cause the device to fall and cause an injury or 
malfunction of the device.

Do not use the unit with power voltage levels other than those 
specified. Failure to follow this may result in fire, electric shock, 
and/or malfunction.

Do not connect devices that exceed the indicated capacity to the 
output contact of the unit. Failure to follow this may result in 
electric shock, fire, and/or malfunction.

Do not touch terminals with wet hands. Failure to follow this 
may result in electric shock.

2

PRECAUTIONS

This manual describes precautions by classifying them based on degrees of danger and 
damage that would be generated if using the unit incorrectly.

Be sure to observe

We categorize these precautions throughout the manual using the following symbols.

Warning

Caution

This indicates the possibility of severe injury, and 
even death, if ignored or a user handles the unit 
incorrectly.

This indicates the possibility of minor injury and/or 
damage to properties, or of a notification delay in your 
system due to false operations and/or non-detection, if 
ignored or a user handles the unit incorrectly.

An action you must do, and information you should keep in mind

A prohibited action, you must not do.

Summary of Contents for PA-5312E

Page 1: ...or damage to the unit if the unit falls as well as prevent the sensor from being tampered Mount the unit on a solid ceiling or wall surfaces where reinforcement materials are used If you mount the unit on non wood materials of plaster board or concrete securely mount it using anchors and mounting screws that match the wall materials Unstable mounting may result in injury and or property damage if ...

Page 2: ...n electric shock fire and or malfunction Do not install the unit in places subject to oil smoke or steam high humidity and or a lot of dust Electricity that travels through these substances may result in fire electric shock and or false operation Ask qualified personnel for any electrical work necessary for installation if required Failure to follow this may result in fire and or electric shock Th...

Page 3: ...ill come off easily Attach the base unit with the arrow pointing to the direction of ceiling Refer to 5 WIRING and connect terminals Twist cover counter clockwise while pushing cover locking lever as the figure to detach cover Snap off limit pin near the parabolic mirror which release the mirror to turn to wall mount area Set area by area selector Put the cover on the channel of cover spacer acces...

Page 4: ...t 1160m 22000ft 6700m 5900ft 1800m 34000ft 10400m AWG 22 Dia 0 65mm AWG 18 Dia 1 0mm AWG 16 Dia 1 25mm 9300ft 2840m 55000ft 16500m 6 AREA SETTING PA 5312E Indicator Ceiling mount Ceiling mount Wall mount PA 5325E Ex In case of 10 3m ceiling mount height and 40 12m range selector should be set at E Ex In case of 13 4m wall mount height and 33 10m range selector should be set at 9 Ex In case of 10 3...

Page 5: ...5 Coverage can be adjusted by turning area selector in accordance with area set chart on the back of sensor unit Loosen base unit locking screw and rotate sensor unit horizontally for adjustment ADJUST UNDER AIMING POSITION DISTANCE ft m WALL 6 5 8 5 10 13 2 0 2 6 3 0 4 0 4 6 8 11 25 7 6 33 10 0 40 12 0 45 13 7 55 16 8 60 18 3 66 20 0 75 22 8 82 25 0 3 5 6 9 3 4 5 7 2 4 5 6 2 3 4 5 2 3 4 5 1 2 3 4...

Page 6: ...TACT CHENGEOVER SETTING OF SENSITIVITY SLIGHT MOTION DETECTION Switch 3 ON N O OFF N C Factory set Switch 6 ON Slight motion OFF Intruder detection Factory set Change alarm contact to N O when sensor is used for an application except security purpose such as light control When operation check shows you high sensitivity of sensor change setting of sensitivity with mode selector and re check operati...

Page 7: ...it The detector reacts to passersby outside Remove the cause Change the installation location Change the installation location Shield sunrays with a blind Readjust the detection area Alarm LED lights though connected units are inactive Poor contact output connection or broken wire Check the wiring Connected units are damaged Check connected units Damaged alarm contact Check alarm output terminals ...

Page 8: ...mm 2 31 59 3 26 83 5mm Ceiling mount Wall mount Mounting hole Ceiling mount horizontal angle adjustment Vertical angle adjustment Sensor locking screw Cover locking screw Silver White 0 18 4 5m m 25 45 30 9 0 2 0 φ7 49 φ192mm φ6 63 φ170mm 0 27 7mm 2 03 52mm 1 60 41mm 1 40 36mm Flush mount attachment BU 5300 Sensor unit Plate Flush mount box Mounting hole 8 Limited Warranty TAKEX products are warra...

Reviews: