4.1.9 SP-## Special Functions
Par. No.
#
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion
index
Type
SP-0#
SP-00
Fault Level
ExpressionLimit
1 set-up
TRUE
-
Uint8
SP-1#
SP-10
Line failure
[0] No function
All set-ups
FALSE
-
Uint8
SP-11
Line Voltage at Input Fault
ExpressionLimit
All set-ups
TRUE
0
Uint16
SP-12
Function at Line Imbalance
[0] Trip
All set-ups
TRUE
-
Uint8
SP-13
Mains Failure Step Factor
1 N/A
All set-ups
TRUE
-1
Uint8
SP-14
Kin. Backup Time Out
60 s
All set-ups
TRUE
0
Uint8
SP-15
Kin. Backup Trip Recovery Level
ExpressionLimit
All set-ups
TRUE
-3
Uint32
SP-2#
SP-23
Typecode Setting
ExpressionLimit
2 set-ups
FALSE
-
Uint8
SP-24
Trip Delay at Current Limit
60 s
All set-ups
TRUE
0
Uint8
SP-25
Trip Delay at Torque Limit
60 s
All set-ups
TRUE
0
Uint8
SP-26
Trip Delay at Drive Fault
ExpressionLimit
All set-ups
TRUE
0
Uint8
SP-28
Production Settings
[0] No action
All set-ups
TRUE
-
Uint8
SP-29
Service Code
0 N/A
All set-ups
TRUE
0
Int32
SP-3#
SP-30
Current Lim Cont, Proportional Gain
100 %
All set-ups
FALSE
0
Uint16
SP-31
Current Lim Contr, Integration Time
ExpressionLimit
All set-ups
FALSE
-3
Uint16
SP-32
Current Lim Ctrl, Filter Time
ExpressionLimit
All set-ups
TRUE
-4
Uint16
SP-35
Stall Protection
[1] Enabled
All set-ups
FALSE
-
Uint8
SP-4#
SP-40
VT Level
66 %
All set-ups
FALSE
0
Uint8
SP-41
Energy Savings Min. Magnetisation
ExpressionLimit
All set-ups
TRUE
0
Uint8
SP-42
Energy Savings Min. Frequency
10 Hz
All set-ups
TRUE
0
Uint8
SP-43
Motor Cosphi
ExpressionLimit
All set-ups
TRUE
-2
Uint16
SP-5#
SP-50
RFI Filter
[1] On
1 set-up
FALSE
-
Uint8
SP-51
DC Link Compensation
ExpressionLimit
1 set-up
TRUE
-
Uint8
SP-52
Fan Operation
[0] Auto
All set-ups
TRUE
-
Uint8
SP-53
Fan Monitor
[1] Warning
All set-ups
TRUE
-
Uint8
SP-55
Output Filter
[0] No Filter
All set-ups
FALSE
-
Uint8
SP-56
Capacitance Output Filter
ExpressionLimit
All set-ups
FALSE
-7
Uint16
SP-57
Inductance Output Filter
ExpressionLimit
All set-ups
FALSE
-6
Uint16
SP-59
Actual Number of Inverter Units
ExpressionLimit
1 set-up
FALSE
0
Uint8
SP-7#
SP-71
Accel Time 1 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
SP-72
Accel Time 1 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
SP-73
Decel Time 1 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
SP-74
Decel Time 1 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
SP-76
Accel/Decel Time 2 Type
[0] Linear
All set-ups
TRUE
-
Uint8
SP-79
Accel Time 2 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
SP-8#
SP-80
Accel Time 2 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
SP-81
Decel Time 2 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
SP-82
Decel Time 2 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
SP-84
Accel/Decel Ramp 3 Type
[0] Linear
All set-ups
TRUE
-
Uint8
SP-87
Accel Time 3 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
SP-88
Accel Time 3 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
Parameter Lists
AF-650 GP Programming Guide
DET-618C
149
4
4