1C1B
Source 1 Phase C Power Factor
-0.999 to 1
---
0.001
F013
0
1C1C
Reserved (4 items)
---
---
---
F001
0
1C20
...Repeated for Source 2
1C40
...Repeated for Source 3
1C60
...Repeated for Source 4
1C80
...Repeated for Source 5
1CA0
...Repeated for Source 6
Source Frequency (Read Only) (6 Modules)
1D80
Frequency for Source 1
2 to 90
Hz
0.001
F003
0
1D82
Frequency for Source 2
2 to 90
Hz
0.001
F003
0
1D84
Frequency for Source 3
2 to 90
Hz
0.001
F003
0
1D86
Frequency for Source 4
2 to 90
Hz
0.001
F003
0
1D88
Frequency for Source 5
2 to 90
Hz
0.001
F003
0
1D8A
Frequency for Source 6
2 to 90
Hz
0.001
F003
0
Breaker Flashover (Read/Write Setting) (2 Modules)
2196
Breaker Flashover 1 Function
0 to 1
---
1
F102
0 (Disabled)
2197
Breaker Flashover 1 Side 1 Source
0 to 5
---
1
F167
0 (SRC 1)
2198
Breaker Flashover 1 Side 2 Source
0 to 6
---
1
F211
0 (None)
2199
Breaker Flashover 1 Status Closed A
0 to 4294967295
---
1
F300
0
219B
Breaker Flashover 1 Status Closed B
0 to 4294967295
---
1
F300
0
219D
Breaker Flashover 1 Status Closed C
0 to 4294967295
---
1
F300
0
219F
Breaker Flashover 1 Voltage Pickup Level
0 to 1.5
pu
0.001
F001
850
21A0
Breaker Flashover 1 Voltage Difference Pickup Level
0 to 100000
V
1
F060
1000
21A2
Breaker Flashover 1 Current Pickup Level
0 to 1.5
pu
0.001
F001
600
21A3
Breaker Flashover 1 Pickup Delay
0 to 65.535
s
0.001
F001
100
21A4
Breaker Flashover 1 Supervision Phase A
0 to 4294967295
---
1
F300
0
21A6
Breaker Flashover 1 Supervision Phase B
0 to 4294967295
---
1
F300
0
21A8
Breaker Flashover 1 Supervision Phase C
0 to 4294967295
---
1
F300
0
21AA
Breaker Flashover 1 Block
0 to 4294967295
---
1
F300
0
21AC
Breaker Flashover 1 Events
0 to 1
---
1
F102
0 (Disabled)
21AD
Breaker Flashover 1 Target
0 to 2
---
1
F109
0 (Self-Reset)
21AE
Reserved (4 items)
---
---
---
F001
0
21B2
...Repeated for breaker flashover 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 Modules)
21E0
Breaker 1 Arcing Current Phase A
0 to 99999999
kA
2
-cyc
1
F060
0
21E2
Breaker 1 Arcing Current Phase B
0 to 99999999
kA
2
-cyc
1
F060
0
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 Modules)
21E4
Breaker 1 Arcing Current Phase C
0 to 99999999
kA
2
-cyc
1
F060
0
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 Modules)
21E6
Breaker 1 Operating Time Phase A
0 to 65535
ms
1
F001
0
21E7
Breaker 1 Operating Time Phase B
0 to 65535
ms
1
F001
0
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 Modules)
21E8
Breaker 1 Operating Time Phase C
0 to 65535
ms
1
F001
0
21E9
Breaker 1 Operating Time
0 to 65535
ms
1
F001
0
21EA
...Repeated for module number 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 Modules)
21EE
...Repeated for module number 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 Modules)
21F0
...Repeated for module number 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 Modules)
21F2
...Repeated for module number 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (6 Modules)
21F4
...Repeated for module number 3
21FE
...Repeated for module number 4
Table B–10: MODBUS MEMORY MAP (Sheet 9 of 65)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for L60
Page 10: ...x L60 Line Phase Comparison System GE Multilin TABLE OF CONTENTS ...
Page 57: ...GE Multilin L60 Line Phase Comparison System 2 27 2 PRODUCT DESCRIPTION 2 3 SPECIFICATIONS 2 ...
Page 58: ...2 28 L60 Line Phase Comparison System GE Multilin 2 3 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Page 482: ...6 26 L60 Line Phase Comparison System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 554: ...10 8 L60 Line Phase Comparison System GE Multilin 10 2 BATTERIES 10 MAINTENANCE 10 ...
Page 674: ...B 110 L60 Line Phase Comparison System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Page 704: ...C 30 L60 Line Phase Comparison System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 720: ...E 10 L60 Line Phase Comparison System GE Multilin E 1 PROTOCOL APPENDIX E E ...
Page 732: ...F 12 L60 Line Phase Comparison System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 742: ...H 8 L60 Line Phase Comparison System GE Multilin H 3 WARRANTY APPENDIX H H ...