38
Code F07012287
USE AND MAINTENANCE
ENGLISH
Fig. 40
1
2
3
6
5
4
Fig. 39
3.7 VIBRATION LEVEL
In conditions of operation compliant with correct use indications, vibrations are not such as to give rise to hazardous
situations.
3.8 CONTROLS TO BE CARRIED OUT UPON RECEPTION OF THE MACHINE
When receiving the machine, make sure that all its parts are intact.
Should there be damaged parts promptly inform the area dealer or directly the manufacturers.
When the machine is delivered, expressly request the following:
a) That the machine be delivered fully assembled (this procedure is necessary as the machine could be shipped partially disassembled for
reasons of bulk).
b) That it is tested at your presence with water only, specifically checking:
• That all guards are present and properly welded to the machine, in particular the pump PTO guard, PTO shaft guards and all rotating
parts.
•
That the suction filter and the inside of the tank are clean and free from processing residues.
•
That no fittings or connections show any visible leaks.
• That all screws are correctly tightened with particular care for those of the drawbar, axle and wheels.
ATTENTION
Depending on the cases, the machine might have disassembled wheels, therefore when reassembling the wheels, the bolts must
be fastened in the order set out in Fig. 39.
• Use a suitable TORQUE WRENCH and tighten the nuts of the
studs in the order set out applying a torque equal to: 270 Nm
(see table 50).
•
Check inflation pressure of the wheels complying with the
manufacturer's instructions (marked on the tyres).
•
Make sure the sizes of the various components are compatible
in relation to the needs of use in the firm. For instance: type
and size of nozzles, filter mesh size related to the nozzles, de
-
livery computer setting, pressure gauge scale definition related
to pressure used, other.
• Make sure the pressure gauge reading scale is connected to
the use pressure which must be at least:
- 0.2 bar for pressure up to 5bar
- 1 bar for pressure between 5 and 20 bar
- 2 bar for pressure higher than 20 bar
c) The main operating instructions are given during testing.
d) If in your region, calibration of the machine coupled to the tractor
intended for use should also be required, this operation must be
officially carried out and documented for professional utilisation
of the machine, according to the laws in force in the area of use.
3.9 FREQUENCY OF FUNCTIONAL CHECKS
ATTENTION
By virtue of the EUROPEAN PARLIAMENT AND COUNCIL DIRECTIVE 2009/128/EC it is obligatory to subject profes-
sional use sprayers to functionality checks and in some cases - depending on local laws - to calibration.