190-01007-C1
GTN Xi Part 23 AML STC Maintenance Manual
Rev. 1
Page 6-12
6.7 Configuration Module (P1001 Only)
The GTN Xi P1001 connector assembly serves as the housing for a configuration module. This section
lists configuration module assemblies.
Table 6-2 Configuration Module Wire Color Reference Chart
NOTE
The pin contacts supplied with the GTN Xi configuration module are specifically made to
accommodate 28 AWG wire. The crimp tool should have the indenter set to the correct
setting when crimping these contacts to the configuration module harness.
Configuration modules are located within the GTN Xi harness connector backshell (item 6, Figure 6-6).
There are two configuration module kits that have been approved for use with GTN Xi. The
P/N 011-00979-00 configuration module kit has a spacer (Figure 6-7). The P/N 011-00979-03
configuration module kit does not use a spacer (Figure 6-6). The P/N 011-00979-03 configuration module
kit is included with the GTN Xi installation kits and is recommended for all replacements. The instructions
for removal/replacement of a configuration module apply equally to either part number. Unless otherwise
noted, refer to the corresponding backshell assembly drawing when performing the following removal and
re-installation steps.
Color
Function
P1001 Contact
Red
Vcc
65
Black
Ground
64
Yellow
Data
62
White
Clock
63