190-01007-C1
GTN Xi Part 23 AML STC Maintenance Manual
Rev. 1
Page 5-22
5.4 Flight Stream Troubleshooting
Table 5-13 Flight Stream Troubleshooting
Problem
Possible Cause
Corrective Action
Unable to pair PED
to Flight Stream
210/510.
Trying to pair with the device
while not on the
Bluetooth
Pairing
page.
Access the
Connext Bluetooth Pairing
page
by pressing
Home > System > Connext Setup
> Flight Stream 210
. If Flight Stream 210 is the
only Bluetooth device, touching
Connext Setup
will automatically open the
Flight Stream 210
page.
Flight Stream paired device
storage is full.
Refer to the list of paired devices and verify that
the queue is not full. If 13 devices have been
previously paired with the Flight Stream,
remove a device from the list to pair the new
device with the Flight Stream.
Ensure that the Flight Stream
has the latest certified
software version.
Check software version and update if there is a
newer approved version.
Flight Stream 210 is
connected but
Connext Setup
page is grayed out.
Flight Stream 210 has lost
communication with the
GTN Xi.
Check that the Flight Stream 210 connector is
fully seated.
Check RS-232 wires and connections between
the GTN Xi and Flight Stream 210.
Check power and ground wires and
connections to the Flight Stream 210.
PED is not
receiving any data
from Flight Stream
210/510.
Devices need to be re-synced
with each other.
1. Access the
Connext Bluetooth Pairing
page by pressing
Home
>
System
>
Connext Setup
.
2. Remove the PED from the list of paired
devices on the GTN Xi.
3. Remove the list of Bluetooth devices on the
PED.
4. Re-pair the devices.
PED is not
receiving data from
the GDL 88
(e.g., ADS
-
B traffic
and FIS-B).
Flight Stream 210 has lost
communication with the GDL
88.
Check that PED is paired to Flight Stream 210.
Refer to the steps above for details.
Check that the Flight Stream 210 connector is
fully seated.
Check RS-422 wires and connections between
the GDL 88 and Flight Stream 210.
Check power and ground wires and
connections to the Flight Stream 210.
Check that the GDL 88 RS-422 port is
configured for Connext Format 1.