9
TAKEOFF TOUR
Selecting COM and VLOC Frequencies
While the 400W-series unit is acquiring a position,
let’s take a minute to dial in the active and standby
frequencies you’ll be using for the first phase of your
flight. The 400W-series display is divided into separate
“windows” (or screen areas), including a COM window,
VLOC window, and the GPS window.
COM Window:
Active Frequency
COM Window:
Standby Frequency
with tuning cursor
VLOC Window:
Active Frequency
Pushing the
small left
knob activates the tuning
cursor in the desired frequency window. To select the
active frequency, you must first enter the frequency
in the standby field, and use the
COM flip-flop
(or
VLOC flip-flop
)
key to move it to the active field.
To change the standby communication (COM) or
VLOC frequency:
1. If the tuning cursor is not currently in the
desired window (COM or VLOC), press the
small left
knob momentarily to switch the
highlight between the COM and VLOC win-
dows. Adjusting the frequencies with the
large
and
small left
knobs will affect the standby
frequency.
2. Turn the
large left
knob to select the desired
megahertz (MHz) value. For example, the
“135” portion of the frequency “135.325”.
3. Turn the
small left
knob to select the desired
kilohertz (kHz) value. For example, the “.325”
portion of the frequency “135.325”.
4. To activate the selected frequency, press the
appropriate
flip-flop
key—COM for commu-
nication frequencies or VLOC for VOR/Localizer
frequencies.
Once you’ve entered the active frequency, simply
repeat steps 1 through 3, above, to enter the standby
frequency. After both communication frequencies have
been entered, you may elect to keep the COM window
‘hot’ by leaving the cursor on the standby frequency, or
move the cursor to the VLOC window by pressing the
small left
knob.
Once you’ve entered the active frequency, simply
repeat steps 1 to 3, above, to enter the standby fre-
quency. After both communication frequencies have
been entered, you may elect to keep the COM window
“hot” by leaving the cursor on the standby frequency,
or move the cursor to the VLOC window by pressing
the
small left
knob.
NOTE:
When selecting VLOC frequencies, the
tuning cursor automatically returns to the COM
window after 30 seconds of inactivity.
These features are only available in the 420W/430W
units.
Selecting COM and VLOC Frequencies
420W / 430W Only
Summary of Contents for GNS 430AW
Page 1: ...Pilot s Guide Reference 400W Series ...
Page 10: ...INTRODUCTION viii Blank Page ...
Page 38: ...28 1 COM Blank Page ...
Page 70: ...2 NAV PAGES 60 Blank Page ...
Page 90: ...4 FLIGHT PLANS 80 Active Flight Plan Shortcuts Blank Page ...
Page 122: ...5 PROCEDURES 112 Blank Page ...
Page 154: ...7 NRST PAGES 144 Nearest Airspaces Blank Page ...
Page 186: ...10 FDE 176 Blank Page ...
Page 213: ......