99
GalStar
Instruction 1.0
•
Sensor Type *:
The options are:
N.Activ, Direct, Group, Commun., NLinear, EC-485, pH-485.
•
Sensor No.:
Enter the number of the sensor of the selected sensor type.
•
Low Alarm Setup
•
High Alarm Setup
•
Alarm Delay – Sec
•
Dep. On Aux.Out.No:
When working with a low energy consumption system a sensor
cannot be permitted to consume up to 20 mA continuously. It is possible to operate the
sensor reading briefly every certain cycle of time. Program an auxiliary output for the
desired cycle and then enter its number here.
Sensor Group (423):
It is possible to define group sensors and then use the group reading for
control and information. Up to four sensors can be defined for a group. The type of group reading
can be: minimum, maximum, average etc. Press “Group Sensor” in the “Sensors Screen – 42” to
access the “Sensor Group - 423” screen. The group readings values of up to 10 groups are shown.
Groups Defin. (6254):
Press “Groups Defin.” in the “previous screen to access:
Screen Explanation:
•
Current Value
: (Information only)
•
Sens. Group Type *:
The options are:
N. Active, Average, Lowest, Highest, Differ
.
- the greatest differential between two sensors of the group, A(-)B – shows the result of
the subtraction of the first sensor in the group (A) minus the reading of the second sensor
in the group (B). If sensors C and D are defined they will be ignored.
•
Sensor in the Group
(4 parameters): Define the sensor type (see above explanation – 42):
Direct, Group, Commun; NLinear
and the sensor number.
6. Gal-Star Software Setup Instructions