50
GalStar
Instruction 1.0
4. Advanced Operation
•
Today Water Mul. % (0-200):
Water multiplication for all the programs in the “Head” for today
only. 200% means the amount is doubled. Please note that zero and 100 do not alter the amount.
This parameter is reset at midnight. If programmed in the “Program Setup”, the “Sequence Setup”
and here, it works according to the order: “program”, “sequence” and then “head”. For example: If the
“Water Multiplication” in the “Head” is 20% and 30% in the program the program will work according
to 30%. This enables setting some programs of the head with different percentages to the general
percentage of the rest of the head.
•
Fix.Water Mul. %:
See the previous item. This parameter is not reset and can only be altered
manually.
•
Cancel Fert (Yes/No):
It is possible to cancel fertilization for all of the programs in the head
without erasing the fertilization program.
•
Pause Irrigat. (Yes/No)
•
Flush Fail.React:
Reactions to a filter flushing failure. The options are:
o
Idle:
No reaction.
o
Alarm:
In the case of failure only issue an alarm but keep on irrigating.
o
Pause:
In the case of failure “pause” only.
o
Fault:
In the case of a failure, issue an alarm and “pause” the irrigation.
Valve/Line Order (162):
(Programmable screen). When starting and stopping the irrigation, the
order of opening/closing the main valve and the irrigation valves is important. In this section you can
define which element (main valve and irrigation valve) opens/closes first and the time difference
between the elements.
Press “Main”>”Head 1”>”Head Consts”>”Valves Order” to access: