40
GalStar
Instruction 1.0
4. Advanced Operation
Group Setup (1343):
Press “Groups Setup” in the “Valve Group Status – 134” screen to access
the “Group Setup - 1343” screen.
Screen Explanation:
•
Valve A-J in Group:
Assign the number of the valve to the group. When running the “Irrigation
Program” using this group, the valves assigned here open and measure the water and fertilizer in the
same way as any other valve.
•
Water Count. No.:
Shows the valve number as assigned by “Valve Group Setup” or in the valve
setup. If this parameter is zero then the water meter of the group is the water meter assigned in the valve
property. Note that all of the valves should have the same water meter in order to work in the same group
otherwise an alarm will be issued. It is highly recommended to define a water meter here.
•
Valve Accumulation (135):
Press “Valve Accumulation” in the “Valves Status – 13” screen to
access the “Valve Accumulation - 135” screen.