91
GalStar
Instruction 1.0
Screen Explanation:
•
System Setup:
The options are:
o
Active:
The normal status.
o
Paused:
The system is stopped, when released it continues from the same position.
o
N.Active:
The system is stopped. All operational parameters (accumulations, next
start time etc.) are reset.
•
Sys. No. for Messages:
The number of system for data collection purposes. In the data
collection program (GalGraph) this number is assigned in order to see the report.
•
Message Cycle-Mnt:
In data collection of a continuous reading element such as water
meters, sensors etc the resolution of the reading (time difference for each point in the
graph) must be defined.
•
Language Setup *:
The Gal-Star controller is capable of working with several languages.
Select the required language.
•
Inputs Sampl:
The rate that the controller reads the inputs. The default is “High”.
•
Sensors Sampl:
The rate that the controller checks the sensor reading. The default is “Low”.
Time Setup (611):
Set the date and time.
Communication Setup (612):
Definition of the communication with the PC (one of the few
functions that can only be carried out in the controller).
•
Controller No.:
The number of the controller for communication.
•
Baud Rate *:
The rate of communication. The same Baud Rate must be defined in both
the controller and the PC. The options are: 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200. When working with direct connection set the Baud Rate to the maximum.
•
Communication Method *:
The options are: Direct, Modem. In most cases select Direct.
6. Gal-Star Software Setup Instructions