TX300 S8 / RX350 S8
Upgrade and Maintenance Manual
259
Hard disk drives / solid state drives
Ê
When working on a tower server, open the HDD bay cover as described in
section
"Removing accessible drive and HDD bay covers" on page 77
.
7.3.7.2
Removing a 3.5-inch HDD module
Figure 165: Disconnecting a 3.5-inch HDD module
Ê
While pressing down on the locking button (1) fold up the lever (2).
I
Thereby, the HDD module is pushed out of its drive bay by about 1 cm
and disconnected from the SAS / SATA backplane.
Ê
Wait about 30 seconds to allow the hard disk drive to spin down.