214
Upgrade and Maintenance Manual
TX300 S8 / RX350 S8
Hard disk drives / solid state drives
7.2.8
Replacing a 2.5-inch HDD / SSD module
V
CAUTION!
●
Only remove an HDD / SSD module during operation if the drive is
not currently being accessed. Observe the indicators on the
HDD / SSD module, as described in the "PRIMERGY
TX300 S8 / RX350 S8 Server" operating manual".
●
Under no circumstances should you remove an HDD / SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 0, 1, 1E, 10, 5, 50, 6 or 60.
An HDD / SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
●
All HDD / SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.2.8.1
Preliminary steps
Ê
"Locating the defective server" on page 57
Ê
When working on a tower server, open the HDD bay cover as described in
section
"Removing accessible drive and HDD bay covers" on page 77
.
Ê
Locate the defective HDD / SSD module as described in section
"Local
diagnostic indicators on the front" on page 60
.
Only applicable for removing intact HDD / SSD modules:
Ê
Before removing a non-defective HDD / SSD module, put the drive into
"Offline" mode using your RAID configuration software.
Customer Replaceable Unit
(CRU)
Average task duration:
5 minutes
Tools:
tool-less
Summary of Contents for PRIMERGY RX350 S8
Page 6: ...Upgrade and Maintenance Manual TX300 S8 RX350 S8 ...
Page 44: ...44 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Before you start ...
Page 160: ...160 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Basic software procedures ...
Page 182: ...182 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Power supply ...
Page 320: ...320 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Hard disk drives solid state drives ...
Page 344: ...344 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Fans ...
Page 484: ...484 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Main memory ...
Page 528: ...528 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Processors ...
Page 644: ...644 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Front panel and external connectors ...
Page 792: ...792 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Appendix ...