TX300 S8 / RX350 S8
Upgrade and Maintenance Manual
389
Expansion cards and backup units
I
Ensure that the GPGPU / coprocessor card power cables have been
connected to the power backplane as described in section
"Connecting
GPGPU / coprocessor card power cables to the power backplane" on
page 384
.
Ê
Press out on the locking latch to disengage the PCI slot bracket locking bar
(1, see close-up).
Ê
Fold up (2) and remove (3) the PCI slot bracket locking bar.
I
The PCI slot mounting bar is no longer required if installing one or two
GPGPU / coprozessor cards. Set aside and save the mounting bar for
future use.
Figure 271: Removing the PCI slot bracket (B)
Ê
Remove the slot brackets from expansion slots 5 and 6.
I
If two GPGPU or coprocessor cards are to be installed, also remove
the slot brackets from expansion slots 7 and 8.
V
CAUTION!
Keep the slot bracket for further use.
Always replace slot brackets into unused PCI slot openings to comply
with applicable EMC regulations and satisfy cooling requirements.
Summary of Contents for PRIMERGY RX350 S8
Page 6: ...Upgrade and Maintenance Manual TX300 S8 RX350 S8 ...
Page 44: ...44 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Before you start ...
Page 160: ...160 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Basic software procedures ...
Page 182: ...182 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Power supply ...
Page 320: ...320 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Hard disk drives solid state drives ...
Page 344: ...344 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Fans ...
Page 484: ...484 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Main memory ...
Page 528: ...528 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Processors ...
Page 644: ...644 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Front panel and external connectors ...
Page 792: ...792 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Appendix ...