TX300 S8 / RX350 S8
Upgrade and Maintenance Manual
173
Power supply
Ê
Push the PSU dummy module into its slot until it locks in place.
V
CAUTION!
Always install dummy modules into unused PSU slots to comply with
applicable EMC regulations and satisfy cooling requirements.
6.4
Replacing PSU modules
V
CAUTION!
●
When replacing a PSU module in a non-redundant PSU
configuration, the server must be switched off first.
●
Ensure to replace a defective PSU module by a new module of the
same type.
I
Note for servers using CMA (Cable Management Arm)
Since the installed CMA is blocking PSU modules, additional steps are
required in order to remove or replace PSU modules:
Ê
Unlock the CMA stopper.
Ê
Remove the CMA stopper with the mounted crossbar.
Ê
Support the CMA stopper, the crossbar and the CMA arm including
cables with your right hand.
Ê
Remove the PSU module and carefully install a new PSU module.
Ê
Remount the complete assembly (CMA stopper, crossbar and CMA
arm) into the rail.
Customer Replaceable Unit
(CRU)
Average task duration:
5 minutes
Tools:
tool-less
Summary of Contents for PRIMERGY RX350 S8
Page 6: ...Upgrade and Maintenance Manual TX300 S8 RX350 S8 ...
Page 44: ...44 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Before you start ...
Page 160: ...160 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Basic software procedures ...
Page 182: ...182 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Power supply ...
Page 320: ...320 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Hard disk drives solid state drives ...
Page 344: ...344 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Fans ...
Page 484: ...484 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Main memory ...
Page 528: ...528 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Processors ...
Page 644: ...644 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Front panel and external connectors ...
Page 792: ...792 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Appendix ...