TX300 S8 / RX350 S8
Upgrade and Maintenance Manual
453
Expansion cards and backup units
9.6.4.2
Removing the BBU holder from the chassis
Figure 348: Removing the BBU holder from the chassis
Ê
Carefully disconnect the BBU cable from the RAID controller.
Ê
Remove the BBU cable from the cable guide.
Ê
Lift up the green locking handle on the BBU holder (1, see close-up) while
sliding the BBU holder towards the server front as far as it will go (2).
I
After that, the fixation bolts on the chassis floor will rest in the wide
ends of the keyhole slots on the holder.
Ê
Lift the BBU holder out of the chassis.
9.6.4.3
Concluding steps
Ê
"Installing the system fan holder" on page 331
Ê
"Installing the system air duct" on page 83
Ê
"Installing the SAS expander board" on page 309
(if applicable)
Ê
"Closing the server" on page 98
Ê
When working on a rack-mounted server:
"Mounting the server in the rack" on page 115
Ê
"Connecting the server to the mains" on page 118
Summary of Contents for PRIMERGY RX350 S8
Page 6: ...Upgrade and Maintenance Manual TX300 S8 RX350 S8 ...
Page 44: ...44 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Before you start ...
Page 160: ...160 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Basic software procedures ...
Page 182: ...182 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Power supply ...
Page 320: ...320 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Hard disk drives solid state drives ...
Page 344: ...344 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Fans ...
Page 484: ...484 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Main memory ...
Page 528: ...528 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Processors ...
Page 644: ...644 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Front panel and external connectors ...
Page 792: ...792 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Appendix ...