788
Upgrade and Maintenance Manual
TX300 S8 / RX350 S8
Appendix
11
Power-on
indicator
green on
Server is switched on and running.
orange on
Server is switched off, but mains voltage
is present (standby mode).
I
After connecting the server to the
mains, it will take about 60
seconds until the server will
switch into standby mode.
With firmware version 7.3.x, two new operating
conditions are indicated: iRMC booting and power-on
delay.
yellow /
orange
flashing
iRMC booting
I
After connecting the server to the
mains (power cord plugged in /
after mains failure) the iRMC will
boot. The system cannot be
switched on, until the iRMC boot
sequence is complete. During
this time, the power-on indicator
will flash yellow / orange.
yellow on
Power-on delay
I
After shutting down, the server
cannot be switched on again right
away. If the On / Off button is
pressed right after shutting down
the server, the power-on indicator
will light up yellow until the delay
period ends and the server will
boot.
Pos. Indicator
Status
Description
Summary of Contents for PRIMERGY RX350 S8
Page 6: ...Upgrade and Maintenance Manual TX300 S8 RX350 S8 ...
Page 44: ...44 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Before you start ...
Page 160: ...160 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Basic software procedures ...
Page 182: ...182 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Power supply ...
Page 320: ...320 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Hard disk drives solid state drives ...
Page 344: ...344 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Fans ...
Page 484: ...484 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Main memory ...
Page 528: ...528 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Processors ...
Page 644: ...644 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Front panel and external connectors ...
Page 792: ...792 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Appendix ...