TX300 S8 / RX350 S8
Upgrade and Maintenance Manual
333
Fans
8.3.1.2
Installing a rear fan module
V
CAUTION!
– Do not remove the air duct in order to install fan modules!
In the below figures, the air duct has only been removed for
illustration purposes.
– For fan redundancy and in order to satisfy cooling requirements,
always install both rear fan modules. Operation with only one rear fan
module is not possible.
Figure 225: Installing a rear fan module (A)
Ê
Fit the first fan module into its bay in the rear fan holder as shown with its
label facing the server rear.
Ê
Gently press down on the fan module until it locks in place (1).