496
Upgrade and Maintenance Manual
TX2560 M2 / RX2560 M2
Converting a tower model to a rack model
Figure 366: Removing the right side cover (B)
Ê
Slide the right side cover towards the server rear as far as it will go.
Ê
Ensure that the three hooks on the right side cover rest in the wide ends of
the slots on the upper chassis edge (see close-up).
Ê
Remove the three hooks on the right side cover from the slots on the upper
chassis edge:
Ê
Using a slotted screw driver, slightly pry up on the middle hook until it
disengages (1).
Ê
Pull up both ends of the right side cover to remove the left and right hooks
from the slots on the upper chassis edge (2).
Ê
Ensure that all cables and components are properly secured inside the
server and that there are no loose pieces.
Ê
Carefully turn the server upside down.
I
At least two people are needed to turn over a fully equipped server.
Remove HDDs and PSUs in order to facilitate the task.
Summary of Contents for PRIMERGY RX2560 M2
Page 6: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 ...
Page 26: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Contents ...
Page 42: ...42 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Before you start ...
Page 110: ...110 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Basic hardware procedures ...
Page 152: ...152 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Power supply unit PSU ...
Page 364: ...364 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Main memory ...
Page 434: ...434 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Accessible drives ...
Page 492: ...492 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 System board and components ...
Page 544: ...544 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Cabling ...
Page 568: ...568 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Appendix ...