TX2560 M2 / RX2560 M2
Upgrade and Maintenance Manual
411
Accessible drives
12.5.2 Removing a slimline ODD or LSD
12.5.2.1 Preliminary steps
Ê
"Removing backup and optical disk media" on page 114
Ê
"Shutting down the server" on page 58
Ê
"Disconnecting the power cord" on page 59
Ê
"Getting access to the component" on page 61
I
The front cover only needs to be removed in order to remove or install
accessible drive dummy covers. If the Multibay will be reinstalled after
removing the slimline ODD or LSD module, the front cover can
remain installed.
Ê
"Removing the system air duct" on page 91
Ê
"Removing the system fan holder" on page 93
12.5.2.2 Removing the Multibay box
Ê
Remove all cables from the slimline ODD.
Ê
Remove the LSD cable from system board connector SMB 1.
Ê
Disengage the accessible drive locking bar as described in section
the accessible drive locking bar" on page 100
.
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Summary of Contents for PRIMERGY RX2560 M2
Page 6: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 ...
Page 26: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Contents ...
Page 42: ...42 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Before you start ...
Page 110: ...110 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Basic hardware procedures ...
Page 152: ...152 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Power supply unit PSU ...
Page 364: ...364 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Main memory ...
Page 434: ...434 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Accessible drives ...
Page 492: ...492 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 System board and components ...
Page 544: ...544 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Cabling ...
Page 568: ...568 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Appendix ...