TX2560 M2 / RX2560 M2
Upgrade and Maintenance Manual
373
Processor (CPU)
Figure 268: Installing the CPU
Ê
Hold the CPU with your thumb and index finger.
Align the arrow on the lower left edge of the CPU with the registration mark
(small triangle) stamped on the CPU socket (see close-up).
Ê
Lower the CPU straight down without tilting or sliding it in the socket.
V
CAUTION!
– Ensure that the CPU is level in the socket.
– Be careful not to touch or bend the pins on the CPU socket.
– Never touch the underside of the CPU. Even minor soiling such
as grease from the skin can impair the CPU’s operation or destroy
the CPU.
– Ensure not to scrape or dent the CPU edges.