Upgrade and Maintenance Manual
TX2560 M2 / RX2560 M2
Basic hardware procedures
4.1.2
Determining the error class
The Local Service Concept (LSC) allows you to identify defective server
components. Failure events are assigned to one of two error classes:
–
Global Error
events that need to be resolved by maintenance personnel
–
Customer Self Service
(CSS) error events that may be resolved by
operating personnel
Global Error and CSS LEDs (see section
"Connectors and indicators" on
) indicate, if the defective component is a customer replaceable unit or
if maintenance personnel needs to be dispatched to replace the part.
I
The indicators also light up in standby mode and after a server restart
due to a power failure.
4.1.2.1
Global Error indicator
Ê
Check the Global Error indicator on the front or connector panel of the
server.
Ê
For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL) as described in section
.
– Software / agent related errors:
Check the ServerView System Monitor, available on Windows or Linux
based servers with ServerView agents installed.
I
For further information, please refer to the "ServerView System
Monitor" user guide.
4.1.2.2
Customer Self Service (CSS) indicator
Ê
Check the CSS indicator on the front panel or connector panel of the server.
Ê
For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL) as described in section
.
Summary of Contents for PRIMERGY RX2560 M2
Page 6: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 ...
Page 26: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Contents ...
Page 42: ...42 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Before you start ...
Page 110: ...110 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Basic hardware procedures ...
Page 152: ...152 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Power supply unit PSU ...
Page 364: ...364 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Main memory ...
Page 434: ...434 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Accessible drives ...
Page 492: ...492 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 System board and components ...
Page 544: ...544 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Cabling ...
Page 568: ...568 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Appendix ...