552
Upgrade and Maintenance Manual
TX2560 M2 / RX2560 M2
Appendix
Using the Indicate LDL button
Ê
Shut down and power off the server.
Ê
Disconnect the AC power cords from the system.
I
It is mandatory to disconnect power cords in order to use the Indicate
LDL functionality.
Ê
Remove the air duct as described in section
"Removing the system air duct"
.
Ê
Press the Indicate LDL button (1) to highlight defective components.
Onboard indicators
The LEDs have the following meaning:
LED Indicator
Meaning
A - Identification
blue on
The server has been highlighted using
ServerView Operations Manager, iRMC web
frontend or the ID button on the front panel
for easy identification
blue flashing
The server has been highlighted for easy
identification using the iRMC (AVR) with
disabled local VGA output.
B - CSS
(Customer Self
Service)
off
No critical event detected (CSS component).
orange on
Prefailure event detected (CSS component).
orange flashing CSS component failure detected.
C - GEL
(Global Error
LED)
off
No critical event detected (non CSS
component).
orange on
Prefailure event detected (non CSS
component).
orange flashing
Non CSS component failure detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server management
software
Summary of Contents for PRIMERGY RX2560 M2
Page 6: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 ...
Page 26: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Contents ...
Page 42: ...42 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Before you start ...
Page 110: ...110 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Basic hardware procedures ...
Page 152: ...152 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Power supply unit PSU ...
Page 364: ...364 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Main memory ...
Page 434: ...434 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Accessible drives ...
Page 492: ...492 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 System board and components ...
Page 544: ...544 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Cabling ...
Page 568: ...568 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Appendix ...