TX2560 M2 / RX2560 M2
Upgrade and Maintenance Manual
425
Accessible drives
Ê
If the removed ultraslim ODD is not to be replaced by a new drive:
Ê
Secure the locking latch to the ultraslim ODD with its two original screws
to the HDD cage (see figure
Ê
Insert the ultraslim ODD dummy cover (see figure
12.6.2.4 Installing the 4x 3.5-inch HDD extension box
Ê
Install the 4x 3.5-inch HDD extension box as described in section
the 4x 3.5-inch HDD extension box" on page 247
12.6.2.5 Concluding steps
Ê
"Installing the system fan holder" on page 94
Ê
"Installing the system air duct" on page 92
Ê
Ê
"Connecting the power cord" on page 87
Ê
"Switching on the server" on page 90
12.6.3 Replacing the ultraslim ODD
12.6.3.1 Preliminary steps
Ê
"Locating the defective server" on page 55
Ê
"Removing backup and optical disk media" on page 114
Ê
"Shutting down the server" on page 58
Ê
"Disconnecting the power cord" on page 59
Upgrade and Repair Unit
(URU)
Hardware: 10 minutes
Tools:
– Phillips PH2 / (+) No. 2 screw driver
– Slotted screw driver (for bending in or out accessible drive
mounting brackets)
Summary of Contents for PRIMERGY RX2560 M2
Page 6: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 ...
Page 26: ...Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Contents ...
Page 42: ...42 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Before you start ...
Page 110: ...110 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Basic hardware procedures ...
Page 152: ...152 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Power supply unit PSU ...
Page 364: ...364 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Main memory ...
Page 434: ...434 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Accessible drives ...
Page 492: ...492 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 System board and components ...
Page 544: ...544 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Cabling ...
Page 568: ...568 Upgrade and Maintenance Manual TX2560 M2 RX2560 M2 Appendix ...