5. Hardware Configurations
Multiple options can be selected in the ETERNUS DX according to the customer's requirements. This chapter de-
scribes the installation conditions and standard installation rules for each component.
Configuration Schematics
The following diagrams show minimum and maximum configurations for ETERNUS DX storage systems.
■
Minimum Configuration
Figure 107 Minimum Configuration Diagram
CE
IOC0
CPU
SW1
BUD
IOC1
CM#0
SW0
IOC0
CPU
SW1
IOC1
CM#1
SW0
CPSU
CPSU
BBU
BUD
Memory
Memory
DE
IOM#0
IOM#1
DPSU
DPSU
PANEL
PANEL
MP
CA
CA
EXP
EXP
EXP
EXP
MP
PANEL:
Operation panel
CE:
Controller Enclosure
CM:
Controller Module
CA:
Channel Adapter
Host Interface
Memory:
Cache Memory
BBU:
Battery Backup Unit
Backup power source in case of power outage
BUD:
Bootup and Utility Device
•
Backup area in case of power outage
•
Storage area for firmware
FAN:
Fan Unit
Cooling fan unit
SW:
Switch
PCI Express switch
IOC:
I/O Controller
Controller to control I/O
167
FUJITSU Storage ETERNUS DX500 S4/DX600 S4, ETERNUS DX500 S3/DX600 S3 Hybrid Storage Systems Design Guide (Basic)
Copyright 2019 FUJITSU LIMITED
P3AM-7722-25ENZ0
Summary of Contents for ETERNUS DX500 S3/DX600 S3